==Spacing drain pipe==
 
==Spacing drain pipe==
 
Laterals drains should be spaced between 3 - 4 m apart. This is based on an analysis of Hooghoudt's equation<ref>H.P.Ritzema, 1994, Subsurface flow to drains. Chapter 8 in: H.P.Ritzema (ed.), Drainage Principles and Applications, Publ. 16, pp. 236-304, International Institute for Land Reclamation and Improvement (ILRI), Wageningen, The Netherlands. ISBN 90-70754-33-9</ref>:
 
Laterals drains should be spaced between 3 - 4 m apart. This is based on an analysis of Hooghoudt's equation<ref>H.P.Ritzema, 1994, Subsurface flow to drains. Chapter 8 in: H.P.Ritzema (ed.), Drainage Principles and Applications, Publ. 16, pp. 236-304, International Institute for Land Reclamation and Improvement (ILRI), Wageningen, The Netherlands. ISBN 90-70754-33-9</ref>:
<math>Drain\ spacing=\sqrt{\frac{8K_{soil}\left(D_{i}-D_{d}\right)\left(D_{d}-D_{w}\right)+4K_{soil}\left(D_{d}-D_{w}\right)^{2}}{q}}</math>
+
<math>Drain\ spacing=\sqrt{\frac{8K_{soil}H\left(D_{i}-D_{d}\right)\left(D_{d}-D_{w}\right)+4K_{soil}\left(D_{d}-D_{w}\right)^{2}}{q}}</math>
    