'''Account for Seasonal Variability''' – Adjust design parameters based on temperature effects on settling velocity.
 
'''Account for Seasonal Variability''' – Adjust design parameters based on temperature effects on settling velocity.
   −
By understanding sedimentation principles and incorporating best practices into stormwater management design, communities can improve water quality and reduce the impact of urban runoff on aquatic ecosystems.
+
===table===
 +
{| class="wikitable"
 +
|-
 +
! Land use
 +
! Number of <br />observations
 +
! Location
 +
! Sample<br />location
 +
! Sample<br />method
 +
! Analytical<br />method
 +
! d10<br />(um)
 +
! d50<br />(um)
 +
! d90<br />(um)
 +
! Source
 +
|-
 +
| Mixed<br />residential
 +
| 66
 +
| GTA
 +
| Storm<br />sewer
 +
| Auto-<br />sampler
 +
| Coulter counter<br />particle analyzer
 +
| 0.9
 +
| 5.9
 +
| 44
 +
| SWAMP
 +
|-
 +
| Parking<br />lot
 +
| 44
 +
| Markham
 +
| Storm<br />sewer
 +
| Auto-<br />sampler
 +
| Coulter counter<br />particle analyzer
 +
| 2.0
 +
| 9.0
 +
| 92
 +
| SWAMP
 +
|-
 +
| Commercial<br />parking lot
 +
| 1
 +
| Calgary
 +
| Storm<br />sewer
 +
| NA
 +
| Coulter counter<br />particle analyzer
 +
| 2.1
 +
| 8.5
 +
| 25.9
 +
|
 +
|-
 +
| Public bus<br />yard
 +
| 11
 +
| Toronto
 +
| Storm<br />sewer
 +
| Auto-<br />sampler
 +
| Micro-imaging
 +
| 4.0
 +
| 19.2
 +
| 154.1
 +
|
 +
|-
 +
| Commerical<br />parking lot
 +
| 45
 +
| Madison,<br />WI
 +
| Storm<br />sewer
 +
| Auto-<br />sampler
 +
| Wet sieve (>32um);<br />particle analyzer (<32um)
 +
| <2
 +
| 55
 +
| 500<br />
 +
|
 +
|-
 +
| Mixed use
 +
| 20
 +
| Madison, <br />WI
 +
| Storm<br />sewer
 +
| Auto-<br />sampler
 +
| Wet sieve (>32um);<br />particle analyzer (<32um)
 +
| <2
 +
| 42
 +
| 200
 +
|
 +
|-
 +
| Parking lot
 +
| 94
 +
| Madison, <br />WI
 +
| Storm<br />sewer
 +
| Auto-<br />sampler
 +
| Wet sieve (>32 um);<br />particle analyzer (<32um)
 +
| 2
 +
| 54
 +
| 350
 +
|
 +
|-
 +
| Parking lot
 +
| 18
 +
| New<br />Hampshire
 +
| Storm<br />sewer
 +
| Auto-<br />sampler
 +
| Particle analyzer
 +
| -
 +
| 46
 +
| -
 +
|
 +
|-
 +
| Mixed use<br />(roads)
 +
| 176
 +
| Ohio
 +
| Catch<br />basin
 +
| Auto-<br />sampler
 +
| Coulter counter<br />particle analyzer
 +
| 11
 +
| 52.5
 +
| 145
 +
|
 +
|-
 +
| Mixed use
 +
| 7
 +
| Toronto<br />
 +
| Storm<br />outfall
 +
| Grab
 +
| Coulter counter<br />particle analyzer
 +
| 4.0
 +
| 16.4
 +
| 55.1
 +
|
 +
|-
 +
| Parking lot
 +
| 12
 +
| Toronto,<br />Vaughan, <br />Brampton
 +
| Direct<br />runoff, <br />man hole
 +
| Grab
 +
| Coulter counter<br />particle analyzer
 +
| 2.6
 +
| 12.4
 +
| 55.2
 +
|
 +
|}