|''A<sub>i''||m<sup>2</sup>||Impermeable area within the catchment
 
|''A<sub>i''||m<sup>2</sup>||Impermeable area within the catchment
 
|-
 
|-
|''d''||m||Depth of the infiltration BMP, total of all components
+
|''d''||m||Depth of the practice, total of all components
 
|-
 
|-
|''A<sub>p''||m<sup>2</sup>||Permeable area (i.e. footprint area of the infiltration BMP)
+
|''A<sub>p''||m<sup>2</sup>||Permeable footprint area of the practice
 
|-
 
|-
|''x''||m||Perimeter of the infiltration BMP
+
|''x''||m||Perimeter of the practice
 
|-
 
|-
|''K''||mm/hr||Saturated hydraulic conductivity of the filter media or fill used in the infiltration BMP  
+
|''K''||mm/hr||Saturated hydraulic conductivity of the filter media or fill used in the practice  
 
|}
 
|}
   −
This spreadsheet tool has been set up to perform all of the infiltration BMP sizing calculations shown below<br>
+
This spreadsheet tool has been set up to perform all of the infiltration practice sizing calculations shown below<br>
 
{{Clickable button|[[Media:Infiltration Sizing.xlsx|Download Infiltration Sizing.xlsx calculator tool]]}}
 