Line 56:
Line 56:
[[File:Jet cleaning.jpg|thumb|Diagram of hydrojetting cleaning apparatus]]
[[File:Jet cleaning.jpg|thumb|Diagram of hydrojetting cleaning apparatus]]
*To permit access by cameras or cleaning apparatus, 90 degree connectors must not be used in subterranean underdrains. Instead 2 x 45 degree connectors, or preferably 3 x 30 degree connectors should be used instead.
*To permit access by cameras or cleaning apparatus, 90 degree connectors must not be used in subterranean underdrains. Instead 2 x 45 degree connectors, or preferably 3 x 30 degree connectors should be used instead.
+
*For the same reason, dual walled perforated pipes with smooth internal walls are highly recommended to reduce the potential snagging of maintenance equipment.
*The recommended distances between clean outs is based on advice for filter beds in the Ontario Building Code<ref>Province of Ontario. (2018). O. Reg. 332/12: BUILDING CODE. Retrieved February 23, 2018, from https://www.ontario.ca/laws/regulation/120332</ref>. However, the access capabilities of difference apparatus and contractors varies and designers are advised to take advice from maintenance operators in this matter.
*The recommended distances between clean outs is based on advice for filter beds in the Ontario Building Code<ref>Province of Ontario. (2018). O. Reg. 332/12: BUILDING CODE. Retrieved February 23, 2018, from https://www.ontario.ca/laws/regulation/120332</ref>. However, the access capabilities of difference apparatus and contractors varies and designers are advised to take advice from maintenance operators in this matter.
−
For the same reason, dual walled perforated pipes with smooth internal walls are necessary to reduce the potential snagging of maintenance equipment.
+
*[[Wells]]
−
===Wells===
−
*[[Wells]], of 100 - 150 mm diameter perforated pipe, should extend to the bottom of the facility.
−
*The exposed tops of all wells should be fitted with lockable caps.
==Material specifications==
==Material specifications==