'''12 April 2019'''
+
''It looks like there is a unit conversion error in the equation: ST=RVCT×Ac×C×0.1. When I do a unit conversion from mm.ha to m3, I find that the conversion factor should be 10, not 0.1.''
+
*You are quite right, thank you. This has now been corrected on the page [[Bioretention: Sizing]].
+
'''7 Feb 2019'''
'''7 Feb 2019'''
''There is no "L" in the equation. Perhaps a second equation for a pipe orifice would help clarify that.''
''There is no "L" in the equation. Perhaps a second equation for a pipe orifice would help clarify that.''