Choker layer

From LID SWM Planning and Design Guide
Jump to navigation Jump to search
medium sized granular, free from fines

In bioretention systems a choker layer of ≥ 100 mm depth is the recommended method to prevent migration of finer filter media into the underlying storage reservoir aggregate. These same mid-sized granular materials are recommended for use in Stormwater planter underdrains and may be useful in the fine grading of foundations courses for permeable pavements.

Suitable materials include:

High performance bedding (HPB)
Clean, angular aggregate screened to between 6 and 10 mm. Widely available and designed specifically for drainage applications. Free from fines by definition.
HL 6
Is a clean, angular aggregate screened between 10 and 20 mm. Free from fines by definition.
Pea Gravel
Rounded natural aggregate, screened between 5 and 15 mm, and washed free from fines.

In most scenarios, a geotextile layer is unnecessary and has been associated with rapid decline and clogging in some circumstances.