Difference between revisions of "Bioretention: Parking lots"

From LID SWM Planning and Design Guide
Jump to navigation Jump to search
m
 
(3 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 
<imagemap>
 
<imagemap>
Image:Bioretention cell.png|thumb|700 px|This is an image map of an extended tree pit, clicking on components will load the appropriate article.
+
File:Bioretention Full Partial infiltration placementswap.png|thumb|600px|'''[[Bioretention: Partial infiltration|Partial infiltration bioretention]]''' cell draining a parking lot. Designs for this type of LID practice vary, but typically include a water storage reservoir, optional choker layer, filter media layer, mulch and vegetation. Other design variations include [[Bioretention: Full infiltration|'''full infiltration''']] and [[Stormwater planters|'''no infiltration''']] configurations which can be explored with their own image maps.  <span style="color:red">'''''Note''': The following is an "image map", feel free to explore the image with your cursor and click on highlighted labels that appear to take you to corresponding pages on the Wiki.''</span>
circle 573 193 88 [[Trees]]
+
 
circle 374 441 89 [[Trees]]
+
 
poly 359 1251 359 1141 249 1083 235 948 276 830 329 714 400 721 466 821 555 721 617 710 668 833 713 972 689 1091 598 1125 580 1245 568 1248 539 1112 412 1115 379 1148 371 1251 [[Trees]]
+
 
rect 435 97 502 541 [[Graminoids: List]]
+
 
rect 436 1171 508 1260 [[Graminoids: List]]
+
rect 1295 2828 1342 3128 [[Underdrains|Underdrain Access Structure]]
poly 351 88 403 99 435 145 410 188 353 202[[Forebays]]
+
rect 1296 1423 1348 1478 [[Underdrains|Underdrain Access Structure]]
poly 571 449 516 464 494 505 515 550 571 563[[Forebays]]
+
rect 1293 3128 1346 3178 [[Underdrains|Underdrain]]
rect 331 110 350 177 [[Curb cuts]]
+
rect 1112 3181 1169 3250 [[Digital technologies|Water Level Sensor]]
rect 574 473 593 538 [[Curb cuts]]
+
rect 1134 3187 1159 3246 [[Digital technologies|Water Level Sensor]]
circle 395 321 13 [[Overflow]]
+
rect 1126 2838 1163 3187 [[Wells|Monitoring Well]]
poly 391 1255 396 1243 410 1249 407 1337 393 1349 2 1343 -1 1329 393 1330 [[Overflow]]
+
rect 1116 1437 1163 1480 [[Wells|Monitoring Well]]
poly 410 1259 411 1334 552 1334 585 1280 582 1251 527 1262 526 1262 [[Bioretention: Filter media]]
+
rect 1295 3183 1348 3254 [[Bioretention: Internal water storage|Internal Water Storage]]
poly 345 1250 389 1258 390 1327 367 1327 344 1284 [[Bioretention: Filter media]]
+
rect 939 1415 1011 1482 [[Overflow|Overflow Outlet]]
rect 406 1335 555 1355 [[Choking layer]]
+
rect 956 2845 1017 3177 [[Overflow|Overflow Outlet]]
rect 369 1356 457 1395 [[Reservoir aggregate]]
+
rect 935 3229 1012 3285 [[Overflow|Overflow Outlet Pipe]]
rect 482 1357 556 1394 [[Reservoir aggregate]]
+
poly 866 326 866 241 1386 241 1386 416 1392 683 1337 620 1270 579 1278 410 1241 339 1078 326 1045 398 1049 400 992 355 [[Mulch|Mulch]]
circle 468 1375 12 [[Underdrain]]
+
poly 870 685 868 610 1000 567 1004 632 [[Mulch|Mulch]]
 +
poly 868 1028 966 1081 1021 1370 864 1485 870 1283 868 1211 870 1136 [[Mulch|Mulch]]
 +
poly 990 1397 1045 1482 1110 1485 1111 1421 [[Mulch|Mulch]]
 +
poly 1214 1389 1263 1419 1339 1440 1390 1446 1384 1491 1161 1497 [[Mulch|Mulch]]
 +
poly 1292 1062 1386 1032 1384 1164 1249 1209 [[Mulch|Mulch]]
 +
rect 1027 379 870 575 [[Stone|Erosion Control - Stone]]
 +
rect 1241 1223 1392 1432 [[Stone|Erosion Control - Stone]]
 +
rect 815 389 868 540 [[Curb cuts|Curb Cut]]
 +
rect 1398 1234 1441 1378 [[Curb cuts|Curb Cut]]
 +
rect 862 685 1388 1038 [[Trees: List|Tree]]
 +
rect 1068 351 1245 648 [[Plant lists|Vegetation]]
 +
rect 1007 1089 1235 1399 [[Plant lists|Vegetation]]
 +
rect 854 1652 1408 2651 [[Trees: List|Tree]]
 +
rect 1064 2684 1227 2822 [[Plant lists|Vegetation]]
 +
rect 862 2863 955 2940 [[Flow through media|Ponding Depth]]
 +
rect 1017 2902 1119 2942 [[Mulch|Mulch]]
 +
rect 1164 2900 1398 2938 [[Mulch|Mulch]]
 +
rect 864 2943 955 3079 [[Bioretention: Filter media|Filter Media]]
 +
rect 1023 2941 1111 3083 [[Bioretention: Filter media|Filter Media]]
 +
rect 1168 2938 1392 3081 [[Bioretention: Filter media|Filter Media]]
 +
rect 866 3083 953 3116 [[Choker layer|Choker Layer]]
 +
rect 1021 3079 1110 3116 [[Choker layer|Choker Layer]]
 +
rect 1168 3085 1386 3116 [[Choker layer|Choker Layer]]
 +
rect 868 3120 955 3185 [[Reservoir aggregate|Clear Stone / Aggregate]]
 +
rect 1023 3114 1113 3189 [[Reservoir aggregate|Clear Stone / Aggregate]]
 +
rect 1170 3116 1388 3191 [[Reservoir aggregate|Clear Stone / Aggregate]]
 +
rect 1045 3252 1363 3309 [[Soil groups|Uncompacted Subgrade Soil]]
 +
rect 900 3289 1047 3309 [[Soil groups|Uncompacted Subgrade Soil]]
 +
 
 +
 
 
</imagemap>
 
</imagemap>
  
 
On commercial, industrial and multi-unit developments, a popular choice is to integrate [[bioretention]] into parking lot landscaped areas. These distributed cells typically accept sheet flow through multiple curb cuts, have shallow depression storage ≤ 100 mm, and a total area of 5 -200 m<sup>2</sup>. Although many parking lot schemes include long linear bioretention cells (≥ 0.6 m wide), infiltration is optimized by having a level grade and a level base, unlike a [[Bioswales|bioswale]].
 
On commercial, industrial and multi-unit developments, a popular choice is to integrate [[bioretention]] into parking lot landscaped areas. These distributed cells typically accept sheet flow through multiple curb cuts, have shallow depression storage ≤ 100 mm, and a total area of 5 -200 m<sup>2</sup>. Although many parking lot schemes include long linear bioretention cells (≥ 0.6 m wide), infiltration is optimized by having a level grade and a level base, unlike a [[Bioswales|bioswale]].
 +
 +
===Winter maintenance===
 +
Salt can be damaging to the planting in parking lot bioretention. To help minimize this, bioretention practices adjacent to parking areas should always have an [[underdrain]] and salt use be reduced through good design and planning of the [[salt management| parking lot]].
  
 
==Gallery==
 
==Gallery==
Line 39: Line 71:
 
*[[Choking layer]]
 
*[[Choking layer]]
 
*[[Reservoir_aggregate|Reservoir]]
 
*[[Reservoir_aggregate|Reservoir]]
 +
*[[underdrain]]

Latest revision as of 20:57, 5 April 2022

Underdrain Access StructureUnderdrain Access StructureUnderdrainWater Level SensorWater Level SensorMonitoring WellMonitoring WellInternal Water StorageOverflow OutletOverflow OutletOverflow Outlet PipeMulchMulchMulchMulchMulchMulchErosion Control - StoneErosion Control - StoneCurb CutCurb CutTreeVegetationVegetationTreeVegetationPonding DepthMulchMulchFilter MediaFilter MediaFilter MediaChoker LayerChoker LayerChoker LayerClear Stone / AggregateClear Stone / AggregateClear Stone / AggregateUncompacted Subgrade SoilUncompacted Subgrade Soil
Partial infiltration bioretention cell draining a parking lot. Designs for this type of LID practice vary, but typically include a water storage reservoir, optional choker layer, filter media layer, mulch and vegetation. Other design variations include full infiltration and no infiltration configurations which can be explored with their own image maps. Note: The following is an "image map", feel free to explore the image with your cursor and click on highlighted labels that appear to take you to corresponding pages on the Wiki.

On commercial, industrial and multi-unit developments, a popular choice is to integrate bioretention into parking lot landscaped areas. These distributed cells typically accept sheet flow through multiple curb cuts, have shallow depression storage ≤ 100 mm, and a total area of 5 -200 m2. Although many parking lot schemes include long linear bioretention cells (≥ 0.6 m wide), infiltration is optimized by having a level grade and a level base, unlike a bioswale.

Winter maintenance[edit]

Salt can be damaging to the planting in parking lot bioretention. To help minimize this, bioretention practices adjacent to parking areas should always have an underdrain and salt use be reduced through good design and planning of the parking lot.

Gallery[edit]

See Also[edit]