Revision as of 17:58, 19 March 2018
This article is specific to Flow-through stormwater planters, vegetated systems that do not infiltrate water to the native soil.
If you are designing a planted system which does infiltrate water, see advice on Bioretention: Sizing.
The dimensions of a stormwater planter are largely predetermined according to the function of the component. As they do not contain a storage reservoir the planters rely more upon careful selection of materials. Both the filter media and the perforations of the pipe play critical roles for flow control.
Component | Recommended depth (with underdrain pipe) | Typical void ratio (VR) |
---|---|---|
Ponding (dp) | ≥ 300 mm | 1 |
Mulch | 75 ± 25 mm |
|
filter media (dm) |
|
0.3 |
Pipe diameter reservoir | Is equal to underdrain pipe diameter | 0.4 |
Pipe bedding (db) | 50 mm (although commonly omitted altogether). | 0.4 |