<onlyinclude>Of the standard granular materials in the standard OPSS.MUNI 1010 only '''Granular O''' is recommended as a substitute for [[reservoir aggregate| clear stone]].  
+
<onlyinclude>Of the standard granular materials in the standard [http://www.raqsb.mto.gov.on.ca/techpubs/ops.nsf/0/0b9aa4d966cac4f9852580820062909e/$FILE/OPSS.MUNI%201010%20Nov%2013.pdf OPSS.MUNI 1010] only '''Granular O''' is recommended as a substitute for [[reservoir aggregate| clear stone]] in LID construction.  
 
{{Textbox|1= Where Granular O is substituted for clear stone in underground reservoir structures, the void ratio used in design calculations shall be '''0.3''' unless laboratory testing proves otherwise.}}
 
{{Textbox|1= Where Granular O is substituted for clear stone in underground reservoir structures, the void ratio used in design calculations shall be '''0.3''' unless laboratory testing proves otherwise.}}
 
Examples of BMPs with underground reservoirs include [[Underdrains]], [[infiltration trenches]], [[permeable paving]], [[infiltration chambers]], [[exfiltration trenches]].  
 
Examples of BMPs with underground reservoirs include [[Underdrains]], [[infiltration trenches]], [[permeable paving]], [[infiltration chambers]], [[exfiltration trenches]].  