[[File:Riser.gif|thumb|A two stage riser with low flow controlled with an orifice and high flow controlled with a weir.]]
[[File:Riser.gif|thumb|A two stage riser with low flow controlled with an orifice and high flow controlled with a weir.]]
+
+
There are many configurations for multistage risers according to the flow control requirements.
+
It is easiest to begin downstream and design with the the highest return period required in mind.
+
e.g. start by specifying the pipe/culvert component to control the 100 year flow.
+
Then to work backwards to size the lip or weir at the top of the structure to meet the next return period flow.
+
+
The riser is then designed with flow through one or more orifices.
<math>
<math>
Line 10:
Line 17:
\end{matrix}\right.
\end{matrix}\right.
</math>
</math>
+
+
{{Plainlist|1=Where:
+
*''Z'' = the depth of ponded water in m,
+
*''Z<sub>0</sub>'' = the elevation of the bottom of the orifice in m,
+
*''H<sub>0</sub>'' = the height of the orifice in m,
+
*''Z<sub>1</sub>'' = the elevation of the weir in m,
+
*''C<sub>w</sub>'' = the weir coefficient,
+
*''L<sub>w</sub>'' = the length of the weir in m,
+
*''C<sub>d</sub>'' = the discharge coefficient of the orifice (often defaulted to 0.6 for a sharp edged orifice),
+