Bioretention: Sizing
(view source)
Revision as of 20:30, 2 April 2018
13 bytes added
,
6 years ago
m
→Calculate the remaining dimensions
Line 67:
Line 67:
==Calculate the remaining dimensions==
==Calculate the remaining dimensions==
* Step 6: Multiply the depth of each separate component by the void ratio and then sum the total to find the 1 dimensional storage (in mm).
* Step 6: Multiply the depth of each separate component by the void ratio and then sum the total to find the 1 dimensional storage (in mm).
−
* Step 7: Calculate the required total storage (m<sup>3</sup>):
+
* Step 7: Calculate the required total storage (
S<sub>T</sub>,
m<sup>3</sup>):
−
<math>
Storage
=RVC_T\times A_c\times C\times 0.1</math>
+
<math>
S_{T}
=RVC_T\times A_c\times C\times 0.1</math>
{{Plainlist|1=Where:
{{Plainlist|1=Where:
*''RVC<sub>T</sub>'' is the Runoff volume control target (mm),
*''RVC<sub>T</sub>'' is the Runoff volume control target (mm),