The maximum flow rate from the BMP may be limited by the hydraulic conductivity of the medium, or by the properties of the perforated [[pipe]].
 
The maximum flow rate from the BMP may be limited by the hydraulic conductivity of the medium, or by the properties of the perforated [[pipe]].
   −
The maximum flow rate through a bed of filter media (''Q<sub>max, m</sub>'', L/s) may be calculated:
+
The maximum flow rate through a bed of filter media (''Q<sub>max, media</sub>'', m<sup>3</sup>/s) may be calculated:
 
<math>Q_{max, m}=\frac{K_{m}\times A_{p}\times \left (\frac{h_{max}}{d_{m}}  \right )}{3600}</math>
 
<math>Q_{max, m}=\frac{K_{m}\times A_{p}\times \left (\frac{h_{max}}{d_{m}}  \right )}{3600}</math>
 
{{Plainlist|1=Where:
 