==Maintenance and inspection==
 
==Maintenance and inspection==
 +
[[File:Jet cleaning.jpg|thumb|Diagram of hydrojetting cleaning apparatus]]
 +
To permit access by cameras or cleaning apparatus, 90 degree connector must not be used in underdrains. Instead 2 x 45 degree couplers, or preferably 3 x 30 degree couplers should be used instead. For the same reason, dual walled perforated pipes with smooth internal walls are necessary. 
 
*[[Wells]], of 100 - 150 mm diameter perforated pipe, should extend to the bottom of the facility.  
 
*[[Wells]], of 100 - 150 mm diameter perforated pipe, should extend to the bottom of the facility.  
 
*The exposed tops of all wells should be fitted with lockable caps.
 