Changes

Jump to: navigation, search

Overflow

6 bytes added, 2 years ago
m
no edit summary
:Higher flows are diverted and do not enter the infiltration practice. A pipe can by used for this, but a weir or [[curb cuts|curb cut]] minimizes clogging and reduces the maintenance frequency.
===Overflow elevation===
The invert of the overflow should be placed at the maximum water surface elevation of the practice. i.e. the maximum ponding depth. A good starting point is around 300 mm over the surface of the practice. However, consideration should be given to public safety and time for the ponded water to drain. See [[Bioretention: Sizing#Additional step for system without underdrain|Bioretention]]
===Options===
Metal grates are recommended (over plastic) in all situations.
|}
===Gallery===
{{:Overflow:Gallery}}

Navigation menu