Changes

Jump to navigation Jump to search
m
Line 35: Line 35:  
* LID practice design [[drawings]] and details;
 
* LID practice design [[drawings]] and details;
 
* [https://sustainabletechnologies.ca/home/erosion-and-sediment-control/ Erosion and sediment control plans];
 
* [https://sustainabletechnologies.ca/home/erosion-and-sediment-control/ Erosion and sediment control plans];
 +
 +
{| class="wikitable sortable"
 +
! Parameter
 +
! Plan
 +
! Detail
 +
! Profile
 +
! Description
 +
|-
 +
| Location
 +
| x
 +
|
 +
|
 +
| Area extent shown on plan view (bump-outs, municipal reserves, private lots, parks)
 +
|-
 +
| Surface area
 +
| x
 +
|
 +
|
 +
| Outlined on plan view drawings and stated in report
 +
|-
 +
| Inlet
 +
| x
 +
| x
 +
|
 +
| shown on plan view and typical details provided (curb cut, flow spreader, ribbon curb)
 +
|-
 +
| Materials
 +
|
 +
| x
 +
|
 +
| Materials specs (soil, drainage layer), depth, hydraulic conductivity, porosity
 +
|-
 +
| Vegetaion
 +
| x
 +
| x
 +
|
 +
| Planting plan and vegetation details (species, mature density, succession plan)
 +
|-
 +
| Outlet
 +
| x
 +
| x
 +
| x
 +
| Underdrain spec and slope, spill elevation, catch basin type and grate, weir type and lcoation, inlet control device details
 +
|-
 +
| Catchment
 +
| x
 +
|
 +
|
 +
| Delineated catchment area directed to bioretention facility
 +
|-
 +
| Subsurface materials
 +
|
 +
| x
 +
|
 +
| Layer oder (filter, reservoir, geotextiles (if using)) and specifications (gradation, hydraulic condcutivity, void space)
 +
|-
 +
| Depth
 +
|
 +
| x
 +
| x
 +
| Depth of each layer, reservoir retention depth (if applicable), surface ponding depth (if applicable)
 +
|-
 +
| Slope
 +
|
 +
| x
 +
| x
 +
| Sub-base slope and surface slope
 +
|-
 +
| Flow Arrows
 +
|
 +
| x
 +
|
 +
| From contributing area and overflow route
 +
|-
 +
| Water depth
 +
|
 +
| x
 +
|
 +
| Ponding depth and water surface elevation durign deisgn storm and maximum prior to overflow
 +
|-
 +
| Inundation
 +
|
 +
| x
 +
|
 +
| Extent of of inundation during design storms
 +
|-
 +
| Erosion control
 +
| x
 +
| x
 +
|
 +
| Located at inlet, outlet if overland spill
 +
|}
    
==Design Information==
 
==Design Information==
8,255

edits

Navigation menu