Changes

Jump to navigation Jump to search
m
no edit summary
Line 1: Line 1:  
Manufacturers of perforated pipe are often able to provide the open area (m<sup>2</sup>) per meter length.  
 
Manufacturers of perforated pipe are often able to provide the open area (m<sup>2</sup>) per meter length.  
   −
<math>Q_{max, p}=B\times C_{d}\times A_{o}\sqrt{2\cdot g\cdot \left ( d_{p} + d_{m} \right )}</math>
+
<math>Q_{max, p}=B\times C_{d}\times A_{o}\sqrt{2\cdot g\cdot \sum d+}</math>
 +
{{Plainlist|1=Where:
 +
*''K<sub>m</sub>'' is the hydraulic conductivity of the filter media (mm/hr),
 +
*''A<sub>p</sub>'' is the area of the practice (m<sup>2</sup>),
 +
*''d<sub>p</sub>'' is the depth of ponding (mm),
 +
*''d<sub>m</sub>'' is the depth of the filter media (mm), and
 +
*''Σ d+'' is the total depth of bioretention components over the perforated pipe (mm) (e.g. ponding/[[mulch]]/[[filter media]]/[[choker layer]]),
 +
}}
8,255

edits

Navigation menu