Changes

Jump to navigation Jump to search
m
Line 63: Line 63:  
* Step 7: Calculate the required total storage (in m<sup>3</sup>):
 
* Step 7: Calculate the required total storage (in m<sup>3</sup>):
   −
<math>Storage=RVC_T\times Catchment area\times0.095</math>
+
<math>Storage=RVC_T\times A_c\times0.095</math>
 
{{Plainlist|1=Where:
 
{{Plainlist|1=Where:
*''RVC<sub>T</sub>''' = Runoff volume control target (mm), and
+
*''RVC<sub>T</sub>''' is the Runoff volume control target (mm), and
* Area (Ha)
+
* ''A<sub>c</sub>'' is the catchment area (Ha)
 
* 0.095 is the product of a typical runoff coefficient for impermeable surfaces (0.95) and the units correction between m<sup>3</sup> and mm.Ha.}}
 
* 0.095 is the product of a typical runoff coefficient for impermeable surfaces (0.95) and the units correction between m<sup>3</sup> and mm.Ha.}}
  