*38.4 comes from multiplying desired drainage time of 96 hours by void ratio of 0.4}}
 
*38.4 comes from multiplying desired drainage time of 96 hours by void ratio of 0.4}}
    +
==Sizing without an underdrain pipe==
 +
# Determine what the planting needs are and assign appropriate depth of media.
 +
# Determine what the pipe diameter needs to be and assign appropriate depth of reservoir.
 +
# Determine maximum possible storage reservoir depth (''d<sub>S</sub>''):
 +
<math>d_{S}=f'\times38.4</math>
 +
{{Plainlist|1=Where:
 +
*''f''' = Design infiltration rate in mm/hr, and
 +
*38.4 comes from multiplying desired drainage time of 96 hours by void ratio of 0.4}}
 +