Line 1: |
Line 1: |
| __NOTOC__ | | __NOTOC__ |
− | | + | <imagemap> |
− | {{#widget:LucidChart
| + | Image:Infiltration.png|thumb|700 px|This is an image map; clicking on components will load the appropriate article. |
− | |guid=631751be-b877-47b3-9117-86a79a5bf2b0 | + | poly 315 507 208 555 317 605 423 555 [[Drainage time]] |
− | |id=.PsMF78kR~Qn | + | rect 210 658 426 730 [[Details]] |
− | }}
| + | rect 568 522 728 594 [[Underdrain]] |
− | | + | poly 73 27 39 75 75 126 179 126 215 78 181 27 [[Infiltration]] |
| + | poly 268 25 235 75 270 123 364 124 395 76 365 25 [[Infiltration: Testing]] |
| + | rect 237 185 397 225 [[Select BMP type]] |
| + | rect 238 266 397 329 [[Bioretention: Sizing]] |
| + | </imagemap> |
| {{textbox| | | {{textbox| |
| {{plainlist| | | {{plainlist| |
Line 29: |
Line 33: |
| !style="background: darkcyan; color: white"|Parameter | | !style="background: darkcyan; color: white"|Parameter |
| |- | | |- |
− | |''D''||hrs||Duration of design storm (for MOECC volume based caclulations set to 1) | + | |''D''||hrs||Duration of design storm (for MOECC volume based calculations set to 1) |
| |- | | |- |
| |''i''||mm/hr||Intensity of design storm (for MOECC volume based calculations use whole storm depth (link to map)) | | |''i''||mm/hr||Intensity of design storm (for MOECC volume based calculations use whole storm depth (link to map)) |
Line 72: |
Line 76: |
| It is best applied to calculate the limited duration ponding on the surface of [[bioretention cells]], [[bioswales]] and [[enhanced grass swales]]. | | It is best applied to calculate the limited duration ponding on the surface of [[bioretention cells]], [[bioswales]] and [[enhanced grass swales]]. |
| To calculate the time (''t'') to fully drain the facility through the footprint area only: | | To calculate the time (''t'') to fully drain the facility through the footprint area only: |
− | <math>t=\frac{nd}{K}</math> | + | <math>t=\frac{d}{K}</math> |
| | | |
| ==Drawdown time to empty facility== | | ==Drawdown time to empty facility== |
| [[file:Hydraulic radius.png|thumb|Three footprint areas of 9 m<sup>2</sup>.<br> | | [[file:Hydraulic radius.png|thumb|Three footprint areas of 9 m<sup>2</sup>.<br> |
− | From left to right x = 12 m, x = 14 m, and x = 16 m]] | + | From left to right x = 12 m, x = 20 m]] |
| The target [[drawdown time]] for the internal storage of an infiltration facility is between 48-72 hours. <br> | | The target [[drawdown time]] for the internal storage of an infiltration facility is between 48-72 hours. <br> |
| For some geometries (e.g. particularly deep facilities or linear facilities), it preferable to account for lateral infiltration. | | For some geometries (e.g. particularly deep facilities or linear facilities), it preferable to account for lateral infiltration. |