Line 13: |
Line 13: |
| :<math>q'=\frac{q}{SCF}</math> | | :<math>q'=\frac{q}{SCF}</math> |
| {{Plainlist|1=Where: | | {{Plainlist|1=Where: |
− | *''q''' = Infiltration coefficient in mm/hr (accounting for SCF) | + | *''q''' = Infiltration coefficient in mm/hr (accounting for ''SCF'') |
| *''SCF'' = Safety correction factor}} | | *''SCF'' = Safety correction factor}} |
| {{:Safety correction factors}} | | {{:Safety correction factors}} |
| ---- | | ---- |
| {| class="wikitable style="border: none; background: none;" | | {| class="wikitable style="border: none; background: none;" |
− | |Determine if there is a constraint to the depth (d) of the bioretention practice: | + | |Determine if there is a constraint to the depth (''d'') of the bioretention practice: |
| {{:Depth to GW}} | | {{:Depth to GW}} |
| |'''or''' if the land area is limited, determine the I/P ratio:<math>R=\frac{A_{c}}{A_{p}}</math> | | |'''or''' if the land area is limited, determine the I/P ratio:<math>R=\frac{A_{c}}{A_{p}}</math> |
Line 27: |
Line 27: |
| |} | | |} |
| ---- | | ---- |
− | {| class="wikitable style="border: none; background: none;" | + | {| class="wikitable style="background: none;" |
| |To calculate the required depth, where the area of the facility is constrained: | | |To calculate the required depth, where the area of the facility is constrained: |
| <math>d=\frac{D\left[Ri-q'\right]}{V_{R}}</math> | | <math>d=\frac{D\left[Ri-q'\right]}{V_{R}}</math> |