The proportion of water entering the bioretention cell under these flow conditions would be::
The proportion of water entering the bioretention cell under these flow conditions would be::
−
<math>R_c=1-\left ( 1-\frac{3}{9.71} \right )^{1.8}= 0.48,\ or\ 48\ %</math>
+
<math>R_c=1-\left ( 1-\frac{3}{9.71} \right )^{1.8}= 0.48</math>
+
+
48% of the 0.08 m<sup>3</sup/s flow would enter the bioretenteion cell through the inlet as designed.