Changes
Jump to navigation
Jump to search
← Older edit
Newer edit →
Curb cuts
(view source)
Revision as of 01:00, 29 September 2017
242 bytes added
,
7 years ago
no edit summary
Line 1:
Line 1:
−
−
==Sizing==
==Sizing==
To completely capture linear flow travelling along a gutter perpendicular to a curb inlet, the inlet must be of width::
To completely capture linear flow travelling along a gutter perpendicular to a curb inlet, the inlet must be of width::
<math>W_T=0.817Q^{0.42}S_{0}^{0.3}\left (\frac{1}{nS_{x}}\right)^{0.6}</math>
<math>W_T=0.817Q^{0.42}S_{0}^{0.3}\left (\frac{1}{nS_{x}}\right)^{0.6}</math>
−
Where the intention is to capture only a proportion of the flow, the ratio of flow entering the
crub
inlet may be calculated::
+
Where the intention is to capture only a proportion of the flow, the ratio of flow entering the
curb
inlet may be calculated::
<math>R_c=1-\left ( 1-\frac{W}{W_T} \right )^{1.8}</math>
<math>R_c=1-\left ( 1-\frac{W}{W_T} \right )^{1.8}</math>
==Example==
==Example==
+
A curb cut of 0.25 m is proposed as an inlet for an offline bioretention cell receiving runoff from an adjacent roadway. The x-slope is 3% and the longitudinal slope of the road is 2%. The design storm produces flow of 0.08 m<sup>3</sup>/s.
+
Jenny Hill
8,255
edits
Navigation menu
Personal tools
English
Log in
Namespaces
Page
Discussion
Variants
Views
Read
View source
View history
More
Search
Navigation
Home
Table of contents
All pages
Recent changes
Responses to comments
Tools
Special pages
Printable version