Changes

Jump to navigation Jump to search
no edit summary
Line 25: Line 25:  
|colspan="2" style="color:red"|'''Material'''
 
|colspan="2" style="color:red"|'''Material'''
 
|-
 
|-
|colspan="2" |'''Pervious Concrete''' ||  ||  ||  ||    ||  ||    ||  ||    ||    ||    ||  ||  ||    ||
+
|colspan="2" style="color:red"|'''Pervious Concrete''' ||  ||  ||  ||    ||  ||    ||  ||    ||    ||    ||  ||  ||    ||
    
|-
 
|-
Line 37: Line 37:  
|-
 
|-
   −
|colspan="2"|'''Porous Asphalt'''  
+
|colspan="2" style="color:red"|'''Porous Asphalt'''  
    
|-
 
|-
Line 44: Line 44:  
|colspan="2" style="text-align: right;| Thickness (mm) || 50-100 || 50-100 || 50-100 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  
 
|colspan="2" style="text-align: right;| Thickness (mm) || 50-100 || 50-100 || 50-100 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  
 
|-
 
|-
|colspan="2"|'''Permeable Pavers'''  
+
|colspan="2" style="color:red"|'''Permeable Pavers'''  
 
|-
 
|-
 
|colspan="2" style="text-align: right;| Diameter of crushed aggregate (mm) || 5 ||  || 5 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  
 
|colspan="2" style="text-align: right;| Diameter of crushed aggregate (mm) || 5 ||  || 5 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  
Line 54: Line 54:  
|colspan="2" style="text-align: right;| Joint widths for pedistrian applications (mm) || < 15 ||  || < 15 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  
 
|colspan="2" style="text-align: right;| Joint widths for pedistrian applications (mm) || < 15 ||  || < 15 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  
 
|-
 
|-
|colspan="2"|'''Interlocking concrete pavers'''  
+
|colspan="2" style="color:red"|'''Interlocking concrete pavers'''  
 
|-
 
|-
|colspan="2" style="text-align: right;|Thickness (mm) || 60-80 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  
+
|colspan="2" style="text-align: right;|Thickness (mm) ||  ||60-80 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  
 
|-
 
|-
|colspan="2"|'''Stone reservoir'''   
+
|colspan="2" style="color:red"| '''Stone reservoir'''   
 
|-
 
|-
 
|colspan="2" style="text-align: right;|Filter course diameter ||  ||  ||  || 10-12 mm ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  
 
|colspan="2" style="text-align: right;|Filter course diameter ||  ||  ||  || 10-12 mm ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  
Line 72: Line 72:  
|colspan="2" style="text-align: right;|Granular subbase stone diameter (mm) || 50 || 50 || 50 || > 50 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  
 
|colspan="2" style="text-align: right;|Granular subbase stone diameter (mm) || 50 || 50 || 50 || > 50 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  
 
|-
 
|-
|colspan="2" style="text-align: right;|Void space ratio || 0.4 ||  || 0.4 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  
+
|colspan="2" style="text-align: right;|Void space ratio ||0.4 ||  || 0.4 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  
 
|-
 
|-
 
|colspan="2" style="text-align: right;|Granular base stone diameter (mm) || 20 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  
 
|colspan="2" style="text-align: right;|Granular base stone diameter (mm) || 20 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  
Line 80: Line 80:  
|-
 
|-
 
|colspan="2" style="text-align: right;|Bedding stone diameter (mm) || 5 || 5 || 5 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  
 
|colspan="2" style="text-align: right;|Bedding stone diameter (mm) || 5 || 5 || 5 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  
|-
+
 
|colspan="2" style="text-align: right;|Void ratio (%) ||  | 0.3-0.4 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||
   
|-
 
|-
 
|colspan="2" style="text-align: right;|Time to drain stone bed, hr ||  || 24-72 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  
 
|colspan="2" style="text-align: right;|Time to drain stone bed, hr ||  || 24-72 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  
 
|-
 
|-
|colspan="2" style="text-align: right;|Thickness (mm) || 40-75 || 40-75 || 40-75 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  
+
|colspan="2" style="text-align: right;|Thickness (mm) ||40-75 || 40-75 || 40-75 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  
 
|-
 
|-
|colspan="2" |'''Geotextile'''  
+
|colspan="2" style="color:red"| '''Geotextile'''  
 
|-
 
|-
|colspan="2" style="text-align: right;|Between stone reseroir and native soil ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  || ||  ||  ||  ||  ||  
+
|colspan="2" style="text-align: right;|Between stone reseroir and native soil ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||   ||  
 
|-
 
|-
|colspan="2" |'''Underdrain (optional), infiltratio rate <15 mm/hr'''  
+
|colspan="2" style="color:red"| '''Underdrain (optional), infiltratio rate <15 mm/hr'''  
 
|-
 
|-
 
|colspan="2" style="text-align: right;|Diameter (mm) || >= 100 || > 200 || >= 100 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  
 
|colspan="2" style="text-align: right;|Diameter (mm) || >= 100 || > 200 || >= 100 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  
Line 110: Line 109:  
|colspan="2" style="color:red"|  '''Emptying Time, hrs.''' ||  ||  ||  || < 72 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  
 
|colspan="2" style="color:red"|  '''Emptying Time, hrs.''' ||  ||  ||  || < 72 ||  ||  ||  ||  ||  ||  ||  ||  ||  ||  
 
|}
 
|}
 +
 +
- '''Note 1''': IP ratio increases when clean roof runoff, or if runoff pre-treated; PICP OA: 5-15%, PC VC:15-35%; PA VC:16-20%
 +
- '''Note 2''': L1-45% runoff reduction credit, L2-75%; PICP: 5-15% OA; CGP: 20-50% OVC; PC: 15-25%; PA: 15-20%