Once the size of cistern has been determined, it can easily be modeled in many open source and proprietary applications. For planning purposes, a RWH system could be integrated into a site plan using STEP's Treatment Train Tool. This tool provides a graphical user interface and simplified inputs on the EPA SWMM model. It is free to download, click image above.
  −
In a typical configuration:
  −
*The catchment (roof) would be 100% impervious
  −
*The rainwater harvesting system would be a 'Storage' Element with the following properties:
  −
**Storage type = No removal
  −
**Lined
  −
**Underlying soil = <em>doesn't matter, can ignore</em>
  −
**Evaporation factor = 0
  −
**Suction head (mm) = 0
  −
**Saturated conductivity (mm/hr) = 0
  −
**Initial soil moisture deficit (fraction) = 0
  −
*The dimensions of the rainwater cistern can be placed into the fields:
  −
#Bottom elevation (m)
  −
#Maximum depth (m)
  −
#Initial water depth (m)
  −
#The Curves table is designed to accommodate ponds of roughly conical dimensions. A rainwater cistern is usually cuboid or cylindrical in shape, so that the area (m<sup>2</sup>) will remain the same throughout the depth.
  −