Line 121:
Line 121:
*''f''' = design infiltration rate (mm/hr)
*''f''' = design infiltration rate (mm/hr)
*''t'' = [[drainage time|time permitted for ponding to infiltrate]] (hrs) (typically 48 hours)}}
*''t'' = [[drainage time|time permitted for ponding to infiltrate]] (hrs) (typically 48 hours)}}
+
+
{| class="wikitable"
+
|+ style="text-align:center;" | Continuous flow dry ponds recommended storage volumes for 60% long-term suspended solid removal (MOE, 2003)<ref> MOE. 2003. Stormwater Management Planning and Design Manual. https://www.ontario.ca/document/stormwater-management-planning-and-design-manual-0/environmental-design-criteria</ref>
+
! Imperviousness of Catchment
+
! Storage Volume (m³/ha)
+
|-
+
| 35%
+
| 90
+
|-
+
| 55%
+
| 150
+
|-
+
| 70%
+
| 200
+
|-
+
| 85%
+
| 240
+
|}