At a minimum, continuous monitoring should be undertaken as part of Assumption and Verification inspections in the following situations:
At a minimum, continuous monitoring should be undertaken as part of Assumption and Verification inspections in the following situations:
{{textbox|
{{textbox|
−
#For infiltration BMPs designed without sub-drains to determine active sub-surface water storage reservoir volume drainage time and filter bed surface infiltration rate.
+
#When little information is available about the effectiveness of a certain type of BMP or treatment train (i.e., combination of BMPs) or when a new technology is being implemented for the first time in a certain context.
−
#For infiltration BMPs designed with flow-restricted sub-drains, to determine sub-drain peak flow rate, active sub-surface water storage reservoir volume drainage time and filter bed surface infiltration rate.
+
#Where the sensitivity of the receiving water warrants a high level of inspection and testing to determine if BMP effluent quality meets design specifications or regulatory criteria.
−
#As part of Forensic inspection and Testing (FIT) work to determine corrective actions for suspected problems with drainage or effluent quality detected through other inspection and testing work.
+
#As part of Forensic inspection and Testing (FIT) work to determine corrective actions for suspected problems with drainage or effluent quality detected through other inspection and testing work.}}
−
#When little information is available about the effectiveness of a certain type of BMP in a certain environmental context, or when a new technology is being implemented for the first time in a certain context or geographic region.
−
#Where the sensitivity of the receiving water warrants a high level of inspection and testing to determine if BMP effluent quality meets design specifications or regulatory criteria.}}
===External guidance on monitoring the performance of stormwater BMPs===