Changes

Jump to navigation Jump to search
Line 330: Line 330:  
|-
 
|-
 
|[[Filter media|Filter bed surface]]
 
|[[Filter media|Filter bed surface]]
|Use an infiltrometer or permeameter to measure field saturated hydraulic conductivity (K<sub>S</sub>) in at least 5 locations or at a rate of one measurement for every 25 m<sup>2</sup> of filter bed surface area, including inlet and lowest elevation areas. Compare mean and individual values to the design specification or trigger value (See Triggers for follow-up and corrective actions below) to determine if follow-up tasks are needed.
+
|Use an infiltrometer or permeameter to measure field saturated hydraulic conductivity (K<sub>S</sub>) in at least 3 locations for areas up to 2,500 m<sup>2</sup> and one additional location for each additional 1,000 m<sup>2</sup> of filter bed surface area, including inlet and lowest elevation areas. Compare mean and individual values to the design specification or trigger value (See Triggers for follow-up and corrective actions below) to determine if follow-up tasks are needed.
 
|-
 
|-
 
|rowspan="2"|'''[[Permeable pavement]]'''
 
|rowspan="2"|'''[[Permeable pavement]]'''