===For full infiltration design, to calculate the total depth of clear stone aggregate layers needed for the water storage reservoir===  
 
===For full infiltration design, to calculate the total depth of clear stone aggregate layers needed for the water storage reservoir===  
The equation for the maximum depth of the stone reservoir (''d<sub>r, max</sub>'', mm) is as follows:  
+
The equation for the maximum depth of the stone reservoir (''d<sub>r, max</sub>'', m) is as follows:  
    
<math>d_{r, max}=\frac{\left[\left ( RVC_{T}\times R \right )+ RVC_{T}-\left(f'\times D\right )\right]}{n}</math>
 
<math>d_{r, max}=\frac{\left[\left ( RVC_{T}\times R \right )+ RVC_{T}-\left(f'\times D\right )\right]}{n}</math>