Changes

Jump to navigation Jump to search
Line 11: Line 11:     
==Concentrated overland flow==
 
==Concentrated overland flow==
Where a [[Curb cuts| curb cut]], [[Downspout disconnection| a disconnected roof downspout]] or a [[Swales| swale]] collects and conveys surface runoff as concentrated flow, which increases the flow rate, one or more of the following pretreatment features should be considered:
+
Where a [[Curb cuts| curb cut]], [[Downspout disconnection| a disconnected roof downspout]] pipe, [[Swales| swale]], trench drain, side inlet catch basin or other pre-fabricated inlet structure collects and conveys runoff as concentrated overland flow, which increases the flow rate, one or more of the following pretreatment features should be considered:
*[[Pretreatment features| Forebays]] (well suited for bioretention cells)
+
* Catch basin or other inlet structure sump;
*[[Sand filters]] (well suited for underground [[infiltration]])
+
* [[Level spreader]];
- Also see [[stone]] for erosion control at inlets.
+
*[[Pretreatment features| Forebays]] (well suited for bioretention cells);
 +
* [[Stone]] and geotextile filter: A shallow excavation on the filter media bed surface at the inlet, lined with geotextile and rip rap or decorative stone cover; and,
 +
*[[Sand filters]] (well suited for underground [[infiltration]]).
    
==Concentrated underground flow==
 
==Concentrated underground flow==

Navigation menu