Changes

Jump to navigation Jump to search
Line 86: Line 86:  
It is best applied to calculate the maximum duration of ponding on the surface of [[bioretention cells]], and upstream of the [[check dams]] of [[bioswales]] and [[enhanced grass swales]] to ensure all surface ponding drains within 48 hours.  
 
It is best applied to calculate the maximum duration of ponding on the surface of [[bioretention cells]], and upstream of the [[check dams]] of [[bioswales]] and [[enhanced grass swales]] to ensure all surface ponding drains within 48 hours.  
 
To calculate the time (''t'') to fully drain surface ponded water through the filter media or planting soil:  
 
To calculate the time (''t'') to fully drain surface ponded water through the filter media or planting soil:  
<math>t=\frac{dp'}{Kf}</math>
+
<math>t=\frac{dp'}{K_{f}}</math>
 
Where <br>  
 
Where <br>  
 
d<sub>p</sub>' is the effective or mean surface ponding depth (mm).<br>
 
d<sub>p</sub>' is the effective or mean surface ponding depth (mm).<br>

Navigation menu