==To calculate the required storage reservoir footprint area where the depth is fixed or constrained (1D drainage)==
==To calculate the required storage reservoir footprint area where the depth is fixed or constrained (1D drainage)==
−
To ensure that the water storage capacity of the facility is available at the onset of a storm event, it is recommended to size the storage reservoir based on the depth of water that will drain via infiltration between storm events. So d<sub>r</sub> can be calculated as <br>:
+
To ensure that the water storage capacity of the facility is available at the onset of a storm event, it is recommended to size the storage reservoir despth, d<sub>r</sub>, based on the depth of water that will drain via infiltration between storm events. So d<sub>r</sub> can be calculated as <br>:
<math>d{r} = (\frac{f'}{1000}) \times t </math><br>
<math>d{r} = (\frac{f'}{1000}) \times t </math><br>