#[[Bioretention]] has a maximum recommended catchment impervious area to practice permeable (footprint) area ratio, R (or I/P ratio) of 20.
 
#[[Bioretention]] has a maximum recommended catchment impervious area to practice permeable (footprint) area ratio, R (or I/P ratio) of 20.
   −
==Size a bioretention cell for constrained depth==
+
==Size a bioretention cell with no underdrain for constrained depth==
 
If there is a constraint to the depth (''d<sub>T</sub>'', m) of the practice, calculate the required footprint area (''A<sub>p</sub>'', m<sup>2</sup>), as:
 
If there is a constraint to the depth (''d<sub>T</sub>'', m) of the practice, calculate the required footprint area (''A<sub>p</sub>'', m<sup>2</sup>), as:
 
<math>A_{p}=\frac{A_i\times i\times D}{(n\times d_{T})+(f'\times D)}</math>
 
<math>A_{p}=\frac{A_i\times i\times D}{(n\times d_{T})+(f'\times D)}</math>