Line 71: |
Line 71: |
| ==Select a surface ponding depth to begin sizing with== | | ==Select a surface ponding depth to begin sizing with== |
| * Step 2: Determine a maximum surface ponding depth (''d<sub>p, max</sub>'') | | * Step 2: Determine a maximum surface ponding depth (''d<sub>p, max</sub>'') |
− | For practices without underdrains: | + | For practices without underdrains, |
| <math>d_{p, max}=f'\times48</math> | | <math>d_{p, max}=f'\times48</math> |
| {{Plainlist|1=Where: | | {{Plainlist|1=Where: |
Line 79: |
Line 79: |
| For practices with underdrains see recommended maximum surface ponding depth for each filter media blend in the table above.<br> | | For practices with underdrains see recommended maximum surface ponding depth for each filter media blend in the table above.<br> |
| * Step 3: Select a design surface ponding depth, d<sub>p</sub>' (m) to begin sizing with<br> | | * Step 3: Select a design surface ponding depth, d<sub>p</sub>' (m) to begin sizing with<br> |
− | For practices with soft (i.e. landscaped) edges and bowl-shaped ponding areas calculate the mean surface ponding depth: | + | For practices with soft (i.e. landscaped) edges and bowl-shaped ponding areas calculate the mean surface ponding depth, |
| <math>d_{p}'=d_{p, max}\times 1/2</math> | | <math>d_{p}'=d_{p, max}\times 1/2</math> |
− | For practices with hard edges and vertical-walled ponding areas (e.g., stormwater planter, soil cell) use the maximum ponding depth: | + | For practices with hard edges and vertical-walled ponding areas (e.g., stormwater planter, soil cell) use the maximum ponding depth, |
| <math>d_{p}'=d_{p, max}</math> | | <math>d_{p}'=d_{p, max}</math> |
| | | |