→Drainage time (3D)Woods Ballard, B., S. Wilson, H. Udale-Clarke, S. Illman, T. Scott, R. Ahsley, and R. Kellagher. 2016. The SuDS Manual. 5th ed. CIRIA, London.
Line 100:
Line 100:
:<math>t=\frac{nA_{p}}{f'P}ln\left [ \frac{\left (d_{T}+ \frac{A_{p}}{P} \right )}{\left(\frac{A_{p}}{P}\right)}\right]</math>
:<math>t=\frac{nA_{p}}{f'P}ln\left [ \frac{\left (d_{T}+ \frac{A_{p}}{P} \right )}{\left(\frac{A_{p}}{P}\right)}\right]</math>
{{Plainlist|1=Where:
{{Plainlist|1=Where:
−
*''n'' is the porosity of the media,
+
*''n'' is the porosity of the
filter
media,
*''A<sub>p</sub>'' is the area of the practice (m<sup>2</sup>),
*''A<sub>p</sub>'' is the area of the practice (m<sup>2</sup>),
*''f''' is the design infiltration rate (mm/hr),
*''f''' is the design infiltration rate (mm/hr),