Changes

Jump to navigation Jump to search
Line 2: Line 2:  
{{TOClimit|2}}
 
{{TOClimit|2}}
 
===Rapid===
 
===Rapid===
Total cistern volume can be estimated by multiplying the depth of design storm....
+
<p>Total cistern volume can be estimated by multiplying the depth of design storm the catchment area. 1 mm of rain over 1 m<sup>2</sup> results in 1 L of runoff.
 +
For example, the 90th percentile event in Barrie is 26 mm, so every 1 m<sup>2</sup> of rooftop will generate 26 L during this storm event. A 2000 m<sup>2</sup> building would generate 54,000 L of runoff. </p>
 +
The designers have three choices:-
 +
<ol>
 +
  <li>Construct a suitably sized concrete vault underground to capture all of the water</li>
 +
  <li>Alter the slope of the roof to create two or more catchments, the smaller catchments may be diverted to plastic or fiberglass cisterns</li>
 +
  <li>Design 1. or 2. Slightly undersized for this storm, but with additional capacity in an infiltration system to capture overflow. Examples include [[Bioretention Cells|bioretention cells]] or [[Infiltration Chambers|infiltration chambers]]. </li> 
 +
</ol>
 +
</p>
 