Line 15: |
Line 15: |
| !Wellhead protection area<ref>|Time-of-travel within wellhead protection areas</ref> | | !Wellhead protection area<ref>|Time-of-travel within wellhead protection areas</ref> |
| |- | | |- |
− | |'''Rain Barrel''' | + | |'''[[Rain barrels|Rain Barrel]''' |
| |Not applicable | | |Not applicable |
| ||5 to 50 m<sup>2</sup>||Not applicable||1||0||NA||Yes||None||No||None | | ||5 to 50 m<sup>2</sup>||Not applicable||1||0||NA||Yes||None||No||None |
| |- | | |- |
− | |'''Cistern''' | + | |'''[[rainwater harvesting|Cistern]]''' |
| |Not applicable | | |Not applicable |
| |1:1||Not applicable||0||0||0||Yes||None||No||None | | |1:1||Not applicable||0||0||0||Yes||None||No||None |
| |- | | |- |
− | |'''Roof downspout disconnection''' | + | |'''[[Downspout disconnection|Roof downspout disconnection]]''' |
| |Not applicable | | |Not applicable |
| |5 to 100 m<sup>2</sup>||Amend if < 15 mm/hr||0.5||5 to 20||1 to 5||Yes||Building Foundation||No||None | | |5 to 100 m<sup>2</sup>||Amend if < 15 mm/hr||0.5||5 to 20||1 to 5||Yes||Building Foundation||No||None |
Line 31: |
Line 31: |
| |5:1 to 20:1||Not a constraint||1 to 2||0 to 1||<15 %||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||Yes||2 yr | | |5:1 to 20:1||Not a constraint||1 to 2||0 to 1||<15 %||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||Yes||2 yr |
| |- | | |- |
− | |'''Bioretention''' | + | |'''[[Bioretention]]''' |
| |1 | | |1 |
− | |5:1 to 15:1||Underdrain recommended<br>if < 15 mm/hr||1 to 2||5 to 10||0 to 2||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||Yes||2 yr | + | |5:1 to 15:1||[[Underdrain]] recommended<br>if < 15 mm/hr||1 to 2||5 to 10||0 to 2||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||Yes||2 yr |
| |- | | |- |
− | |'''Stormwater planters''' | + | |'''[[Stormwater planters]]''' |
| |Not applicable | | |Not applicable |
| |5:1||Not applicable||1 to 2||2 to 5||0 to 2||Yes||Building Foundation, Trees||No||None | | |5:1||Not applicable||1 to 2||2 to 5||0 to 2||Yes||Building Foundation, Trees||No||None |
| |- | | |- |
− | |'''Vegetated filter strip''' | + | |'''[[Vegetated filter strip]]''' |
| |1 | | |1 |
| |5:1||Amend if < 15 mm/hr||0 to 1||15 to 20||1 to 5||No||None||No||None | | |5:1||Amend if < 15 mm/hr||0 to 1||15 to 20||1 to 5||No||None||No||None |
| |- | | |- |
− | |'''Permeable pavement''' | + | |'''[[Permeable pavement]]''' |
| |1 | | |1 |
| |1:1 to 1.2:1||Underdrain recoomended <br> if < 15 mm/hr||0.5 to 1||0||1 to 5||No||4m-Underground Utilities<br>Drinking Water Wellhead<br>Protection Areas||Yes||2 Yr | | |1:1 to 1.2:1||Underdrain recoomended <br> if < 15 mm/hr||0.5 to 1||0||1 to 5||No||4m-Underground Utilities<br>Drinking Water Wellhead<br>Protection Areas||Yes||2 Yr |
| |- | | |- |
− | |'''Enhanced grass swale (has checkdams)''' | + | |'''[[Enhanced grass swale]](has checkdams)''' |
| |1 | | |1 |
| |5:1 to 10:1||Not applicable||1 to 3||5 to 15||0.5 to 6||No||4m- Building Foundation<br>Underground Utilities||Yes||None | | |5:1 to 10:1||Not applicable||1 to 3||5 to 15||0.5 to 6||No||4m- Building Foundation<br>Underground Utilities||Yes||None |
| |- | | |- |
− | |'''Dry swale (Bioswale)''' | + | |'''[[Dry swale]] (Bioswale)''' |
| |1 | | |1 |
| |5:1 to 15:1||Underdrain recommended <br> if < 15 mm/hr||1 to 3||5 to 10||0.5 to 6||No||4m (3m if impermeable liner<br>is used)Building foundation,<br> Underground utilities, drinking<br>water wellhead protection areas||Yes||2 Yr | | |5:1 to 15:1||Underdrain recommended <br> if < 15 mm/hr||1 to 3||5 to 10||0.5 to 6||No||4m (3m if impermeable liner<br>is used)Building foundation,<br> Underground utilities, drinking<br>water wellhead protection areas||Yes||2 Yr |
| |- | | |- |
− | |'''Perforated pipe system''' | + | |'''[[Perforated pipe system]]''' |
| |1 | | |1 |
| |5:1 to 10:1||Not a constraint||1 to 3||0||< 15%||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||Yes||2 Yr | | |5:1 to 10:1||Not a constraint||1 to 3||0||< 15%||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||Yes||2 Yr |
| |} | | |} |