Changes

Jump to navigation Jump to search
m
no edit summary
Line 1: Line 1: −
<ul><li>Material specifications should conform to Ontario Provincial Standard Specification (OPSS) 1860 for Class II geotextile fabrics.</li>
+
[[File: Geotextile-GSI.JPG|thumb|The properties of geotextiles vary widely.]]
<li>Fabrics should be woven monofilament or non-woven needle punched. Woven slit film and non-woven heat bonded fabrics should not be used as they are prone to clogging.</li>
+
See [[Clogging]] for notes on their application in LID structures.  
</ul>
  −
<p>Primary considerations are:
  −
<ol>
  −
<li>Maximum forces that will be exerted on the fabric (i.e., what tensile, tear and puncture strength ratings are required?);</li>
  −
<li>Load bearing ratio of the underlying native soil (i.e. is the geotextile needed to prevent downward migration of aggregate into the native soil?);</li>
  −
<li>Texture (i.e., grain size distribution) of the overlying fill material; and</li>
  −
<li>Permeability of the native soil</li>
  −
<li>Suitable apparent opening size (AOS) for non-woven fabrics, or percent open area (POA) for woven fabrics, to maintain water flow even with sediment and microbial film build-up;</li>
  −
</ol>
     −
<table class="table table-bordered">
+
Geotextiles can be used to prevent downward migration of smaller particles in to larger aggregates, and slump of heavier particles into finer underlying courses.
<caption><strong>Recommended criteria for selection of geotextile fabric</strong></caption>
+
The formation of biofilm on geotextiles has also been shown to improve water quality:
<tr class="success"><th>Percent media passing 0.075 mm (#200 sieve)</th><th>Non-woven fabric apparent opening size (AOS, mm)</th><th>Woven fabric percent open area (POA, %)</th><th>Permittivity (sec<sup>-1</sup>)</th></tr>
+
*By degrading petroleum hydrocarbons<ref>Newman AP, Coupe SJ, Spicer GE, Lynch D, Robinson K. MAINTENANCE OF OIL-DEGRADING PERMEABLE PAVEMENTS: MICROBES, NUTRIENTS AND LONG-TERM WATER QUALITY PROVISION. https://www.icpi.org/sites/default/files/techpapers/1309.pdf. Accessed July 17, 2017.</ref>
  <tr><td align="center" valign="middle">>85</td><td align="center" valign="middle" rowspan = 2>≤ 0.3</td><td align="center" valign="middle">Not recommended</td><td align="center" valign="middle" rowspan = 2>0.1</td></tr>
+
*By reducing organic pollutant and nutrient concentrations <ref>Paul P, Tota-Maharaj K. Laboratory Studies on Granular Filters and Their Relationship to Geotextiles for Stormwater Pollutant Reduction. Water. 2015;7(4):1595-1609. doi:10.3390/w7041595.</ref>
  <tr><td align="center" valign="middle">50 - 85</td><td align="center" valign="middle" rowspan = 3>≥ 4</td></tr>
+
*When installing geotextiles an overlap of 150 - 300 mm should be used.
  <tr><td align="center" valign="middle">15 - 50</td><td align="center" valign="middle" rowspan = 3>≤ 0.6</td><td align="center" valign="middle">0.2</td></tr>
+
Material specifications should conform to OPSS 1860 for Class II geotextile fabrics
  <tr><td align="center" valign="middle">5 - 15</td><td align="center" valign="middle" rowspan =2>0.5</td></tr>
+
<ref>ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 1860 MATERIAL SPECIFICATION FOR GEOTEXTILES. 2012. http://www.raqsb.mto.gov.on.ca/techpubs/OPS.nsf/0/2ccb9847eb6c56738525808200628de1/$FILE/OPSS%201860%20Apr12.pdf. Accessed July 17, 2017</ref>.
  <tr><td align="center" valign="middle">≤ 5</td><td align="center" valign="middle">≥ 10</td></tr>
+
*Fabrics should be woven monofilament or non-woven needle punched.
  </table>
+
*Woven slit film and non-woven heat bonded fabrics should not be used, as they are prone to clogging.
</p>
+
In choosing a product, consider:
 +
#The maximum forces that will be exerted on the fabric (i.e., what tensile, tear and puncture strength ratings are required?),
 +
#The load bearing ratio of the underlying native soil (i.e. is the geotextile needed to prevent downward migration of aggregate into the native soil?),
 +
#The texture (i.e., grain size distribution) of the overlying and underlying materials, and
 +
#The suitable apparent opening size (AOS) for non-woven fabrics, or percent open area (POA) for woven fabrics, to maintain water flow even with sediment and microbial film build-up.
    +
{|class="wikitable"
 +
|-
 +
|+Recommended criteria for selection of geotextile fabric
 +
|-
 +
!Percent soil/filter media passing 0.075 mm (#200 sieve)
 +
!Non-woven fabric apparent opening size (AOS, mm)
 +
!Woven fabric percent open area (POA, %)
 +
!Permittivity (sec<sup>-1</sup>)
 +
|-
 +
|>85||≤ 0.3||-||0.1
 +
|-
 +
|50 - 85||≤ 0.3||≥ 4||0.1
 +
|-
 +
|15 - 50||≤ 0.6||≥ 4||0.2
 +
|-
 +
|5 - 15||≤ 0.6||≥ 4||0.5
 +
|-
 +
|≤ 5||≤ 0.6||≥ 10||0.5
 +
|}
 +
===Performance research===
 +
http://www.mdpi.com/2073-4441/7/4/1595/htm
 +
----
 
[[category:materials]]
 
[[category:materials]]
8,255

edits

Navigation menu