Changes
Jump to navigation
Jump to search
← Older edit
Newer edit →
Bioretention: Sizing
(view source)
Revision as of 20:30, 2 April 2018
13 bytes added
,
6 years ago
m
→Calculate the remaining dimensions
Line 67:
Line 67:
==Calculate the remaining dimensions==
==Calculate the remaining dimensions==
* Step 6: Multiply the depth of each separate component by the void ratio and then sum the total to find the 1 dimensional storage (in mm).
* Step 6: Multiply the depth of each separate component by the void ratio and then sum the total to find the 1 dimensional storage (in mm).
−
* Step 7: Calculate the required total storage (m<sup>3</sup>):
+
* Step 7: Calculate the required total storage (
S<sub>T</sub>,
m<sup>3</sup>):
−
<math>
Storage
=RVC_T\times A_c\times C\times 0.1</math>
+
<math>
S_{T}
=RVC_T\times A_c\times C\times 0.1</math>
{{Plainlist|1=Where:
{{Plainlist|1=Where:
*''RVC<sub>T</sub>'' is the Runoff volume control target (mm),
*''RVC<sub>T</sub>'' is the Runoff volume control target (mm),
Jenny Hill
8,255
edits
Navigation menu
Personal tools
Log in
Namespaces
Page
Discussion
Variants
Views
Read
View source
View history
More
Search
Navigation
Home
Table of contents
All pages
Recent changes
Responses to comments
Tools
Special pages
Printable version