Changes

Jump to navigation Jump to search
no edit summary
Line 15: Line 15:  
!style="background: cyan; color: black"|Wellhead Protection Area<ref>|Time-of-travel within wellhead protection areas</ref>
 
!style="background: cyan; color: black"|Wellhead Protection Area<ref>|Time-of-travel within wellhead protection areas</ref>
 
|-
 
|-
 
+
!style="background: #FFFDF5; color: black"|Rain Barrel
!Rain Barrel
   
!Not applicable
 
!Not applicable
 
!|[5 to 50 m<sup>2</sup>]||Not applicable||1||0||NA||Yes||None||None||None
 
!|[5 to 50 m<sup>2</sup>]||Not applicable||1||0||NA||Yes||None||None||None
 
|-
 
|-
!Cistern
+
!style="background: #FFFDF5; color: black: black"|Cistern
 
!Not applicable
 
!Not applicable
 
!|1:1||Not applicable||0||0||0||Yes||None||None||None
 
!|1:1||Not applicable||0||0||0||Yes||None||None||None
    
|-
 
|-
!Roof Downspout Disconnection
+
!style="background: #FFFDF5; color: black"|Roof Downspout Disconnection
 
!Not applicable
 
!Not applicable
 
!|[5 to 100 m<sup>2</sup>]||Amend if < 15 mm/hr||0.5||5 to 20||1 to 5||Yes||Building Foundation||None||None
 
!|[5 to 100 m<sup>2</sup>]||Amend if < 15 mm/hr||0.5||5 to 20||1 to 5||Yes||Building Foundation||None||None
 
|-
 
|-
!Soakaway, Infiltration Trench or Chamber
+
!style="background: #FFFDF5; color: black"|Soakaway, Infiltration Trench or Chamber
 
!1
 
!1
 
!|5:1 to 20:1||Not a constraint||1 to 2||0 to 1||<15 %||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||1 m||2 yr
 
!|5:1 to 20:1||Not a constraint||1 to 2||0 to 1||<15 %||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||1 m||2 yr
 
|-
 
|-
!Bioretention
+
!style="background: #FFFDF5; color: black"|Bioretention
 
!1
 
!1
 
!|5:1 to 15:1||Underdrain required<br>if < 15 mm/hr||1 to 2||5 to 10||0 to 2||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||1 m||2 yr
 
!|5:1 to 15:1||Underdrain required<br>if < 15 mm/hr||1 to 2||5 to 10||0 to 2||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||1 m||2 yr
 
|-
 
|-
!Biofilter (Filtration only Bioretention Design)
+
!style="background: #FFFDF5; color: black"|Biofilter (Filtration only Bioretention Design)
 
!Not applicable
 
!Not applicable
 
!|5:1||Not applicable||1 to 2||2 to 5||0 to 2||Yes||Building Foundation, Trees||None||None
 
!|5:1||Not applicable||1 to 2||2 to 5||0 to 2||Yes||Building Foundation, Trees||None||None
 
|-
 
|-
!Vegetated Filter Strip
+
!style="background: #FFFDF5; color: black"|Vegetated Filter Strip
 
!1
 
!1
 
!|5:1||Amend if < 15 mm/hr||0 to 1||15 to 20||1 to 5||No||None||None||None
 
!|5:1||Amend if < 15 mm/hr||0 to 1||15 to 20||1 to 5||No||None||None||None
 
|-
 
|-
!Permeable Pavement
+
!style="background: #FFFDF5; color: black"|Permeable Pavement
 
!1
 
!1
 
!|1:1 to 1.2:1||Underdrain Required <br> if < 15 mm/hr||0.5 to 1||0||1 to 5||No||4m-Underground Utilities<br>Drinking Water Wellhead<br>Protection Areas||1 m||2 Yr
 
!|1:1 to 1.2:1||Underdrain Required <br> if < 15 mm/hr||0.5 to 1||0||1 to 5||No||4m-Underground Utilities<br>Drinking Water Wellhead<br>Protection Areas||1 m||2 Yr
 
|-
 
|-
!Enhanced Grass Swale
+
!style="background:#FFFDF5; color: black"|Enhanced Grass Swale
 
!1
 
!1
 
!|5:1 to 10:1||Not applicable||1 to 3||5 to 15||0.5 to 6||No||4m- Building Foundation<br>Underground Utilities||1 m||None
 
!|5:1 to 10:1||Not applicable||1 to 3||5 to 15||0.5 to 6||No||4m- Building Foundation<br>Underground Utilities||1 m||None
 
|-
 
|-
!Dry Swale (Bioswale)
+
!style="background: #FFFDF5; color: black"|Dry Swale (Bioswale)
 
!1
 
!1
 
!|5:1 to 15:1||Underdrain Required <br> if < 15 mm/hr||1 to 3||5 to 10||0.5 to 6||No||4m (3m if impermeable liner<br>is used)Building foundation,<br> Underground utilities, drinking<br>water wellhead protection areas||1 m||2 Yr
 
!|5:1 to 15:1||Underdrain Required <br> if < 15 mm/hr||1 to 3||5 to 10||0.5 to 6||No||4m (3m if impermeable liner<br>is used)Building foundation,<br> Underground utilities, drinking<br>water wellhead protection areas||1 m||2 Yr
 
|-
 
|-
!Perforated Pipe System
+
!style="background: #FFFDF5; color: black"|Perforated Pipe System
 
!1
 
!1
 
!|5:1 to 10:1||Not a constraint||1 to 3||0||< 15%||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||1 m||2 Yr
 
!|5:1 to 10:1||Not a constraint||1 to 3||0||< 15%||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||1 m||2 Yr
 
|}
 
|}

Navigation menu