Changes

Jump to navigation Jump to search
no edit summary
Line 1: Line 1: −
  −
   
==Sizing==
 
==Sizing==
 
To completely capture linear flow travelling along a gutter perpendicular to a curb inlet, the inlet must be of width::
 
To completely capture linear flow travelling along a gutter perpendicular to a curb inlet, the inlet must be of width::
 
<math>W_T=0.817Q^{0.42}S_{0}^{0.3}\left (\frac{1}{nS_{x}}\right)^{0.6}</math>
 
<math>W_T=0.817Q^{0.42}S_{0}^{0.3}\left (\frac{1}{nS_{x}}\right)^{0.6}</math>
   −
Where the intention is to capture only a proportion of the flow, the ratio of flow entering the crub inlet may be calculated::
+
Where the intention is to capture only a proportion of the flow, the ratio of flow entering the curb inlet may be calculated::
 
<math>R_c=1-\left ( 1-\frac{W}{W_T} \right )^{1.8}</math>
 
<math>R_c=1-\left ( 1-\frac{W}{W_T} \right )^{1.8}</math>
 
   
 
   
 
==Example==
 
==Example==
 +
A curb cut of 0.25 m is proposed as an inlet for an offline bioretention cell receiving runoff from an adjacent roadway. The x-slope is 3% and the longitudinal slope of the road is 2%. The design storm produces flow of 0.08 m<sup>3</sup>/s.
    +
     