To completely capture linear flow travelling along a gutter perpendicular to a curb inlet, the inlet must be of width::
To completely capture linear flow travelling along a gutter perpendicular to a curb inlet, the inlet must be of width::
<math>W_T=0.817Q^{0.42}S_{0}^{0.3}\left (\frac{1}{nS_{x}}\right)^{0.6}</math>
<math>W_T=0.817Q^{0.42}S_{0}^{0.3}\left (\frac{1}{nS_{x}}\right)^{0.6}</math>
−
Where the intention is to capture only a proportion of the flow, the ratio of flow entering the
crub
inlet may be calculated::
+
Where the intention is to capture only a proportion of the flow, the ratio of flow entering the
curb
inlet may be calculated::
<math>R_c=1-\left ( 1-\frac{W}{W_T} \right )^{1.8}</math>
<math>R_c=1-\left ( 1-\frac{W}{W_T} \right )^{1.8}</math>
==Example==
==Example==
+
A curb cut of 0.25 m is proposed as an inlet for an offline bioretention cell receiving runoff from an adjacent roadway. The x-slope is 3% and the longitudinal slope of the road is 2%. The design storm produces flow of 0.08 m<sup>3</sup>/s.
+