*''f''' = design infiltration rate (mm/hr)
 
*''f''' = design infiltration rate (mm/hr)
 
*''t'' = [[drainage time|time permitted for ponding to infiltrate]] (hrs) (typically 48 hours)}}
 
*''t'' = [[drainage time|time permitted for ponding to infiltrate]] (hrs) (typically 48 hours)}}
 +
 +
{| class="wikitable"
 +
|+ style="text-align:center;" | Continuous flow dry ponds recommended storage volumes for 60% long-term suspended solid removal (MOE, 2003)<ref> MOE. 2003. Stormwater Management Planning and Design Manual. https://www.ontario.ca/document/stormwater-management-planning-and-design-manual-0/environmental-design-criteria</ref>
 +
! Imperviousness of Catchment
 +
! Storage Volume (m³/ha)
 +
|-
 +
| 35%
 +
| 90
 +
|-
 +
| 55%
 +
| 150
 +
|-
 +
| 70%
 +
| 200
 +
|-
 +
| 85%
 +
| 240
 +
|}
    