<math>
 +
Q=
 +
\left\{\begin{matrix}
 +
0, & Z\leq Z_{0} \\
 +
C_{w}L_{w}\left ( Z-Z_{0} \right )^{1.5}, & Z_{0}\leq Z\leq Z_{0}+H_{0}\\
 +
C_{d}A_{0}\sqrt{2g\left (Z-Z_{0}-0.5H_{0}\right)}, & Z_{0}+H_{0}\leq Z\leq Z_{1}\\
 +
C_{w}L_{w}\left ( Z-Z_{1} \right )^{1.5}+C_{d}A_{0}\sqrt{2g\left (Z-Z_{1}\right)}, & Z_{1}<Z
 +
\end{matrix}\right.
 +
</math>