Difference between revisions of "Level spreaders"
Jump to navigation
Jump to search
Jenny Hill (talk | contribs) m |
|||
(11 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
− | [[File:Levelspread.jpg|thumb|This clever design incorporates a level spreading device after a [[curb cut]] has | + | [[File:Levelspread.jpg|thumb|This clever design incorporates a level spreading device after a [[curb cut]] has narrowed the flow path. This kind of treatment train approach would provide an opportunity to provide [[pretreatment]] at the point of concentration. Photo credit: [https://www.pca.state.mn.us/featured/when-it-rains-it-flows MPCA] ]] |
+ | [[File:Level spreader diagram.jpg|thumb|Diagram from Wikimedia commons. Credit: U.S. Army Corps of Engineers, Construction Engineering Research Laboratory]] | ||
− | Level spreaders should conform to the following design criteria in order to ensure non-erosive sheet flow into vegetated areas such as [[vegetated filter strips]], | + | Level spreaders should conform to the following design criteria in order to ensure non-erosive sheet flow into vegetated areas such as [[vegetated filter strips]], [[Bioretention|bioretention]], [[swales]] or forested conservation areas<ref>Hathaway, J. M., & Hunt, W. F. (2006). Level Spreaders : Overview , Design , and Maintenance.</ref>. |
− | The length of the level spreader should be determined by the type of | + | The length of the level spreader should be determined by the design storm inflow rate and type of landscape downstream: |
− | * 1.4 m of level spreader length per every 0.01 | + | * 1.4 m of level spreader length per every 0.01 m³/s of inflow when draining to a [[vegetated filter strips|vegetated filter strip]], [[Bioretention| bioretention]], [[Swale| swale]] or grassed area; |
− | * 4.3 m of level spreader length per every 0.01 | + | * 4.3 m of level spreader length per every 0.01 m³/s of inflow when draining to a forested conservation area. |
* The minimum level spreader length is 4 m and the maximum is 40 m. | * The minimum level spreader length is 4 m and the maximum is 40 m. | ||
− | * The level spreader lip should be concrete, wood or pre-fabricated metal | + | * The level spreader lip should be concrete, wood or pre-fabricated metal. |
− | * The ends of the level spreader section should be tied back into the slope to avoid [[overflow]] scouring or erosion around the ends | + | * The ends of the level spreader section should be tied back into the slope to avoid [[overflow]] scouring or erosion around the ends. |
− | * The width of the level spreader | + | * The width of the level spreader should be the greater of 300 mm or three times the diameter of the inflow pipe. |
− | + | * The depth should be the greater of 200 mm or half the inflow pipe diameter. | |
+ | |||
+ | ==References== | ||
+ | [[Category:Pretreatment]] |
Latest revision as of 20:41, 27 September 2022
Level spreaders should conform to the following design criteria in order to ensure non-erosive sheet flow into vegetated areas such as vegetated filter strips, bioretention, swales or forested conservation areas[1].
The length of the level spreader should be determined by the design storm inflow rate and type of landscape downstream:
- 1.4 m of level spreader length per every 0.01 m³/s of inflow when draining to a vegetated filter strip, bioretention, swale or grassed area;
- 4.3 m of level spreader length per every 0.01 m³/s of inflow when draining to a forested conservation area.
- The minimum level spreader length is 4 m and the maximum is 40 m.
- The level spreader lip should be concrete, wood or pre-fabricated metal.
- The ends of the level spreader section should be tied back into the slope to avoid overflow scouring or erosion around the ends.
- The width of the level spreader should be the greater of 300 mm or three times the diameter of the inflow pipe.
- The depth should be the greater of 200 mm or half the inflow pipe diameter.
References[edit]
- ↑ Hathaway, J. M., & Hunt, W. F. (2006). Level Spreaders : Overview , Design , and Maintenance.