Difference between revisions of "Level spreaders"
Jump to navigation
Jump to search
Dean Young (talk | contribs) |
|||
(2 intermediate revisions by one other user not shown) | |||
Line 5: | Line 5: | ||
The length of the level spreader should be determined by the design storm inflow rate and type of landscape downstream: | The length of the level spreader should be determined by the design storm inflow rate and type of landscape downstream: | ||
− | * 1.4 m of level spreader length per every 0.01 m³/s of inflow | + | * 1.4 m of level spreader length per every 0.01 m³/s of inflow when draining to a [[vegetated filter strips|vegetated filter strip]], [[Bioretention| bioretention]], [[Swale| swale]] or grassed area; |
− | * 4.3 m of level spreader length per every 0.01 m³/s of inflow when | + | * 4.3 m of level spreader length per every 0.01 m³/s of inflow when draining to a forested conservation area. |
* The minimum level spreader length is 4 m and the maximum is 40 m. | * The minimum level spreader length is 4 m and the maximum is 40 m. | ||
* The level spreader lip should be concrete, wood or pre-fabricated metal. | * The level spreader lip should be concrete, wood or pre-fabricated metal. | ||
Line 12: | Line 12: | ||
* The width of the level spreader should be the greater of 300 mm or three times the diameter of the inflow pipe. | * The width of the level spreader should be the greater of 300 mm or three times the diameter of the inflow pipe. | ||
* The depth should be the greater of 200 mm or half the inflow pipe diameter. | * The depth should be the greater of 200 mm or half the inflow pipe diameter. | ||
− | + | ||
+ | ==References== | ||
+ | [[Category:Pretreatment]] |
Latest revision as of 20:41, 27 September 2022
Level spreaders should conform to the following design criteria in order to ensure non-erosive sheet flow into vegetated areas such as vegetated filter strips, bioretention, swales or forested conservation areas[1].
The length of the level spreader should be determined by the design storm inflow rate and type of landscape downstream:
- 1.4 m of level spreader length per every 0.01 m³/s of inflow when draining to a vegetated filter strip, bioretention, swale or grassed area;
- 4.3 m of level spreader length per every 0.01 m³/s of inflow when draining to a forested conservation area.
- The minimum level spreader length is 4 m and the maximum is 40 m.
- The level spreader lip should be concrete, wood or pre-fabricated metal.
- The ends of the level spreader section should be tied back into the slope to avoid overflow scouring or erosion around the ends.
- The width of the level spreader should be the greater of 300 mm or three times the diameter of the inflow pipe.
- The depth should be the greater of 200 mm or half the inflow pipe diameter.
References[edit]
- ↑ Hathaway, J. M., & Hunt, W. F. (2006). Level Spreaders : Overview , Design , and Maintenance.