Before beginning the sizing calculations most of the following parameters must be known or estimated.  
+
This article describes recommended design approaches when available space for the practice is constrained.<br>
The exceptions are the depth (''d<sub>T</sub>'') and practice permeable (footprint) area (''A<sub>p</sub>''), as only one of these is required to find the other.  
+
<br>
Note that some of these parameters are limited:
+
Before beginning the sizing calculations certain parameters must be known or estimated. See [[Bioretention: Sizing]] for parameter descriptions and conceptual diagram illustrating key components of bioretention practices. Note that some of these parameters are limited:
 
#The ''maximum'' total depth will be limited by construction practices i.e. not usually > 2 m.
 
#The ''maximum'' total depth will be limited by construction practices i.e. not usually > 2 m.
 
#The ''maximum'' total depth may be limited by the [[Infiltration| conditions underground]] e.g. the groundwater or underlying geology/infrastructure.
 
#The ''maximum'' total depth may be limited by the [[Infiltration| conditions underground]] e.g. the groundwater or underlying geology/infrastructure.
Line 8: Line 8:
  
 
==Size a bioretention cell receiving flows directly to the storage reservoir for a constrained depth==
 
==Size a bioretention cell receiving flows directly to the storage reservoir for a constrained depth==
If there is a constraint to the depth (''d<sub>T</sub>'') of the practice, calculate the required practice footprint area (''A<sub>p</sub>''), as:
+
If there is a constraint to the depth (''d<sub>T</sub>'') of the practice, calculate the required storage reservoir footprint area (''A<sub>r</sub>''), as:
<math>A_{p}=\frac{A_i\times i\times D}{(d_{T}'\times n')+(f'\times D)}</math>
+
<math>A_{r}=\frac{i\times D\times A_i}{(d_{r}\times n')+(f'\times D)}</math>
 
{{Plainlist|1=Where:
 
{{Plainlist|1=Where:
*''A<sub>p</sub>'' = Area of the infiltration practice (m<sup>2</sup>)
+
*''A<sub>r</sub>'' = Area of the infiltration practice storage reservoir (m<sup>2</sup>)
 
*''A<sub>i</sub>'' = Catchment impervious area (m<sup>2</sup>)
 
*''A<sub>i</sub>'' = Catchment impervious area (m<sup>2</sup>)
 
*''D'' = Duration of design storm (h)
 
*''D'' = Duration of design storm (h)
 
*''i'' = Intensity of design storm (mm/h)
 
*''i'' = Intensity of design storm (mm/h)
 
*''f''' = [[design infiltration rate]] (m/h)
 
*''f''' = [[design infiltration rate]] (m/h)
*''n''' = Effective porosity of the fill materials within the active storage component(s) of practice, depth-weighted mean
+
*''n''' = Effective porosity of the fill material in the storage reservoir of the practice
*''d<sub>T</sub>''' = Total depth available between the elevation of the invert of the underdrain perforated pipe and one (1) metre above the seasonally high water table or top of bedrock  (m) or other value determined to be suitable through groundwater mounding analysis.}}<br>
+
*''d<sub>r</sub>'' = Storage reservoir depth, based on depth available between the elevation of the invert of the underdrain perforated pipe and one (1) metre above the seasonally high water table or top of bedrock  (m) or other value determined to be suitable through groundwater mounding analysis.}}<br>
 
If R is greater than 20, consider decreasing catchment impervious area (A<sub>i</sub>) by draining less area to the practice.
 
If R is greater than 20, consider decreasing catchment impervious area (A<sub>i</sub>) by draining less area to the practice.
  
==Size a bioretention cell with no underdrain for constrained ground area==
+
==Size a bioretention cell where drainage area and practice area are fixed==
 
If the land area is limited, determine the I/P ratio, which is the ratio of catchment impervious area (A<sub>i</sub>) to practice pervious footprint area (A<sub>p</sub>):
 
If the land area is limited, determine the I/P ratio, which is the ratio of catchment impervious area (A<sub>i</sub>) to practice pervious footprint area (A<sub>p</sub>):
 
:<math>R=\frac{A_{i}}{A_{p}}</math>
 
:<math>R=\frac{A_{i}}{A_{p}}</math>
Line 29: Line 29:
 
*''A<sub>i</sub>'' = Catchment impervious area in m<sup>2</sup>}}
 
*''A<sub>i</sub>'' = Catchment impervious area in m<sup>2</sup>}}
  
Then calculate the required depth (''d<sub>T</sub>''), as:
+
Then calculate the required storage reservoir depth (''d<sub>r</sub>''), as:
<math>d_{T}=\frac{D \left[ (R\times i)-f'\right]}{n'}</math>
+
<math>d_{r}=\frac{D \left[ (R\times i)-f'\right]}{n'}</math>
  
 
{{Plainlist|1=Where:
 
{{Plainlist|1=Where:
Line 36: Line 36:
 
*''i'' = Intensity of design storm (m/h)
 
*''i'' = Intensity of design storm (m/h)
 
*''f''' = Design infiltration rate (m/h)  
 
*''f''' = Design infiltration rate (m/h)  
*''n''' = Effective porosity of the fill materials within the practice, depth weighted mean
+
*''n''' = Effective porosity of the storage reservoir fill material}}
*''d<sub>T</sub>'' = Total depth of infiltration practice (m).}}
+
These equations assume that infiltration occurs primarily through the base of the facility.<br>
The following equations assume that infiltration occurs primarily through the base of the facility.  
+
<br>
They may be easily applied for any shape and size of infiltration facility, in which the reservoir storage is filled with aggregate. 
+
This spreadsheet tool has been set up to perform all of the infiltration practice sizing calculations shown above.<br>
 
+
{{Clickable button|[[Media:Infiltration Sizing 20220617 locked (1).xlsx|Download the infiltration practice sizing tool]]}}
This spreadsheet tool has been set up to perform all of the infiltration BMP sizing calculations shown above<br>
 
{{Clickable button|[[Media:Infiltration Sizing 20200525 locked.xlsx|Download new infiltration practice sizing tool]]}}
 
  
 
==Calculate drawdown time==
 
==Calculate drawdown time==
Line 48: Line 46:
 
Perimeter = 12 m (left) Perimeter = 20 m (right)]]
 
Perimeter = 12 m (left) Perimeter = 20 m (right)]]
  
{{Clickable button|[[Media:Darcy Drainage.xlsx|Download Darcy Drainage Time.xlsx calculator tool]]}}
+
{{Clickable button|[[Media:Darcy drainage_20200528_locked.xlsx|Download the Darcy drainage time calculator tool]]}}
  
 
In some situations, it may be possible to reduce the size of the bioretention required, by accounting for rapid drainage. Typically, this is only worth exploring over sandy soils with rapid infiltration.  
 
In some situations, it may be possible to reduce the size of the bioretention required, by accounting for rapid drainage. Typically, this is only worth exploring over sandy soils with rapid infiltration.  
 
Note that narrow, linear bioretention features drain faster than round or blocky footprint geometries.  
 
Note that narrow, linear bioretention features drain faster than round or blocky footprint geometries.  
*Begin the drainage time calculation by dividing the area of the practice (''A<sub>p</sub>'') by the perimeter (''x'').
+
*Begin the drainage time calculation by dividing the storage reservoir area of the practice (''A<sub>r</sub>'') by the perimeter (''x'').
 
*Use the following equation to estimate the time (''t'') to fully drain the facility:  
 
*Use the following equation to estimate the time (''t'') to fully drain the facility:  
:<math>t=\frac{nA_{p}}{f'x}ln\left [ \frac{\left (d_{T}+ \frac{A_{p}}{x} \right )}{\left(\frac{A_{p}}{x}\right)}\right]</math>
+
:<math>t=\frac{nA_{r}}{f'x}ln\left [ \frac{\left (d_{r}+ \frac{A_{r}}{x} \right )}{\left(\frac{A_{r}}{x}\right)}\right]</math>
 
{{Plainlist|1=Where:
 
{{Plainlist|1=Where:
*''n'' is the porosity of the fill materials within the practice, depth weighted mean
+
*''n'' is the porosity of the storage reservoir fill material
*''A<sub>p</sub>'' is the area of the practice (m<sup>2</sup>),
+
*''A<sub>r</sub>'' is the storage reservoir footprint area (m<sup>2</sup>),
*''f''' is the design infiltration rate (mm/hr),  
+
*''f''' is the design infiltration rate of the native soil (mm/h),  
 
*''x'' is the perimeter of the practice (m), and
 
*''x'' is the perimeter of the practice (m), and
*''d<sub>T</sub>'' is the total depth of the practice, including the ponding zone (m).}}
+
*''d<sub>r</sub>'' is the depth of the storage reservoir (m).}}
  
This 3 dimensional equation makes use of the hydraulic radius (''A<sub>p</sub>''/''x''), where ''x'' is the perimeter (m) of the facility. <br>
+
This 3 dimensional equation makes use of the hydraulic radius (''A<sub>r</sub>''/''x''), where ''x'' is the perimeter (m) of the facility. <br>
 
Maximizing the perimeter of the facility directs designers towards longer, linear shapes such as [[bioswales]].   
 
Maximizing the perimeter of the facility directs designers towards longer, linear shapes such as [[bioswales]].   
  
 
[[category: modeling]]
 
[[category: modeling]]
 
[[category: infiltration]]
 
[[category: infiltration]]

Latest revision as of 15:49, 27 June 2022

This article describes recommended design approaches when available space for the practice is constrained.

Before beginning the sizing calculations certain parameters must be known or estimated. See Bioretention: Sizing for parameter descriptions and conceptual diagram illustrating key components of bioretention practices. Note that some of these parameters are limited:

  1. The maximum total depth will be limited by construction practices i.e. not usually > 2 m.
  2. The maximum total depth may be limited by the conditions underground e.g. the groundwater or underlying geology/infrastructure.
  3. The minimum total depth will be limited by the need to support vegetation (e.g not less than 0.6 m to support deep rooting perennials and shrubs).
  4. Bioretention has a maximum recommended catchment impervious area to practice permeable (footprint) area ratio, R (or I/P ratio) of 20.

Size a bioretention cell receiving flows directly to the storage reservoir for a constrained depth[edit]

If there is a constraint to the depth (dT) of the practice, calculate the required storage reservoir footprint area (Ar), as:

Where:

  • Ar = Area of the infiltration practice storage reservoir (m2)
  • Ai = Catchment impervious area (m2)
  • D = Duration of design storm (h)
  • i = Intensity of design storm (mm/h)
  • f' = design infiltration rate (m/h)
  • n' = Effective porosity of the fill material in the storage reservoir of the practice
  • dr = Storage reservoir depth, based on depth available between the elevation of the invert of the underdrain perforated pipe and one (1) metre above the seasonally high water table or top of bedrock (m) or other value determined to be suitable through groundwater mounding analysis.


If R is greater than 20, consider decreasing catchment impervious area (Ai) by draining less area to the practice.

Size a bioretention cell where drainage area and practice area are fixed[edit]

If the land area is limited, determine the I/P ratio, which is the ratio of catchment impervious area (Ai) to practice pervious footprint area (Ap):

Where:

  • R = Ratio of catchment impervious area to practice pervious footprint area, also referred to as I/P ratio
  • Ap = Practice pervious footprint area in m2
  • Ai = Catchment impervious area in m2

Then calculate the required storage reservoir depth (dr), as:

Where:

  • D = Duration of design storm (h)
  • i = Intensity of design storm (m/h)
  • f' = Design infiltration rate (m/h)
  • n' = Effective porosity of the storage reservoir fill material

These equations assume that infiltration occurs primarily through the base of the facility.

This spreadsheet tool has been set up to perform all of the infiltration practice sizing calculations shown above.
Download the infiltration practice sizing tool

Calculate drawdown time[edit]

Two footprint areas of 9 m2.
Perimeter = 12 m (left) Perimeter = 20 m (right)

Download the Darcy drainage time calculator tool

In some situations, it may be possible to reduce the size of the bioretention required, by accounting for rapid drainage. Typically, this is only worth exploring over sandy soils with rapid infiltration. Note that narrow, linear bioretention features drain faster than round or blocky footprint geometries.

  • Begin the drainage time calculation by dividing the storage reservoir area of the practice (Ar) by the perimeter (x).
  • Use the following equation to estimate the time (t) to fully drain the facility:

Where:

  • n is the porosity of the storage reservoir fill material
  • Ar is the storage reservoir footprint area (m2),
  • f' is the design infiltration rate of the native soil (mm/h),
  • x is the perimeter of the practice (m), and
  • dr is the depth of the storage reservoir (m).

This 3 dimensional equation makes use of the hydraulic radius (Ar/x), where x is the perimeter (m) of the facility.
Maximizing the perimeter of the facility directs designers towards longer, linear shapes such as bioswales.