<math>Q=\frac{2}{3}C_{d}\cdot L\sqrt{2g}\cdot H^{\frac{3}{2}}</math>
 
<math>Q=\frac{2}{3}C_{d}\cdot L\sqrt{2g}\cdot H^{\frac{3}{2}}</math>
 
{{Plainlist|1=Where:  
 
{{Plainlist|1=Where:  
*''C<sub>d</sub>''= discharge coefficient (default 0.62 for a 'sharp edge).  
+
*''C<sub>d</sub>'' = discharge coefficient (default 0.62 for a 'sharp edge).  
 
*''L'' = Length of the weir (m)
 
*''L'' = Length of the weir (m)
 
*''g'' = Acceleration due to gravity (9.81 m/s<sup>2</sup>)
 
*''g'' = Acceleration due to gravity (9.81 m/s<sup>2</sup>)
 
*''H'' = Height of water over the weir (m)}}
 
*''H'' = Height of water over the weir (m)}}
 +
 +
==More flow related pages==
 +
*[[Flow in a swale]]
 +
*[[Flow through perforated pipe]]
 +
*[[Flow through an orifice]]

Latest revision as of 17:16, 3 July 2019

The most common form of weir in LID practices is a rectangular weir, in the form of a check dam or flow control in a swale or other open channel.

The flow (Q), may be calculated by measuring the height of water on the sill of the weir:

Where:

  • Cd = discharge coefficient (default 0.62 for a 'sharp edge).
  • L = Length of the weir (m)
  • g = Acceleration due to gravity (9.81 m/s2)
  • H = Height of water over the weir (m)