Line 9: |
Line 9: |
| ===Constraints=== | | ===Constraints=== |
| Infiltration practices are not recommended: | | Infiltration practices are not recommended: |
− | #Where the bedrock is within 1 m below the bottom of the proposed BMP, | + | #over swelling clays or unstable sub-soils, |
− | #Where the seasonal high groundwater level comes within 1 m below the bottom of the proposed BMP,<br>Or in areas where increased infiltration will result in elevated groundwater levels, which can be demonstrated to damage critical utilities or private property,
| + | #over contaminated soils or sites with high risk of contamination from onsite activities, |
− | #Over swelling clays or unstable sub-soils,
| + | #in flood prone areas where the wastewater system is sensitive to groundwater conditions causing sewer backups, and where LID BMPs have been found to be ineffective, |
− | #Over contaminated soils or sites with high risk of contamination from onsite activities, | + | #in areas where the ecology and natural hydrology are dependent upon surface water, |
− | #In flood prone areas where the wastewater system is sensitive to groundwater conditions causing sewer backups, and where LID BMPs have been found to be ineffective, | + | #in areas where increased infiltration will result in elevated groundwater levels, which can be demonstrated to damage critical utilities or private property, or |
− | #In areas where the ecology and natural hydrology are dependent upon surface water, | + | #where prohibitions and/or restrictions exist per approved Source Protection Plans (see MOECC guidance). |
− | #Where prohibitions and/or restrictions exist per approved Source Protection Plans (see MOECC guidance). | + | Infiltration facilities should be designed with drainage modifications where: |
| + | #the underlying bedrock is within 1 m below the bottom of the proposed BMP, or |
| + | #the seasonal high groundwater level comes within 1 m below the bottom of the proposed BMP. |
| ===Designing within constraints=== | | ===Designing within constraints=== |
| {{TextBox|1= Infiltration can still be optimized over 'tight' soils with infiltration rates ≤ 15 mm/hr: | | {{TextBox|1= Infiltration can still be optimized over 'tight' soils with infiltration rates ≤ 15 mm/hr: |