Line 21: | Line 21: | ||
* 0.4 for aggregate | * 0.4 for aggregate | ||
|- | |- | ||
− | | [[Bioretention: Filter media| | + | | [[Bioretention: Filter media|Filter media]] (''d<sub>m</sub>'') |
| | | | ||
* 300 mm to support turf grass (and accept only rainwater/roof runoff) | * 300 mm to support turf grass (and accept only rainwater/roof runoff) |
Revision as of 01:24, 14 July 2020
This article is specific to flow-through stormwater planters, vegetated systems that do not infiltrate water to the native soil.
If you are designing a planted system which does infiltrate water, see advice on Bioretention: Sizing.
The dimensions of a stormwater planter are largely predetermined according to the function of the component. As they do not contain a storage reservoir the planters rely more upon careful selection of materials. Both the filter media and the perforations of the pipe play critical roles for flow control.
Component | Recommended depth (with underdrain pipe) | Typical porosity (n) |
---|---|---|
Ponding (dp) | ≥ 300 mm | 1 |
Mulch | 75 ± 25 mm |
|
Filter media (dm) |
|
0.35 |
Pipe diameter reservoir | Is equal to underdrain pipe diameter | 0.4 |
Pipe bedding (db) | 50 mm (although commonly omitted altogether). | 0.4 |