Changes

Jump to navigation Jump to search
m
Line 38: Line 38:  
|Drainage Area  
 
|Drainage Area  
 
|Sustaining vegetation, volumetric turnover
 
|Sustaining vegetation, volumetric turnover
|5 Ha (≥10 Ha preferred)
+
|style="text-align: left|5 Ha (≥10 Ha preferred)
 
|-
 
|-
 
|Treatment Volume  
 
|Treatment Volume  
 
|Provision of appropriate level of protection (Table 3.2)
 
|Provision of appropriate level of protection (Table 3.2)
|See Table 3.2
+
|style="text-align: left|See Table 3.2
 
|-
 
|-
 
|Active Storage
 
|Active Storage
 
|Detention
 
|Detention
|Suspended solids settling 24 hrs (12 hrs if in conflict with min. orifice size)
+
|style="text-align: left|Suspended solids settling 24 hrs (12 hrs if in conflict with min. orifice size)
 
|-
 
|-
 
|Forebay  
 
|Forebay  
 
|Pre-treatment  
 
|Pre-treatment  
|
+
|style="text-align: left|
 
#Minimum depth: 1 m;
 
#Minimum depth: 1 m;
 
#Sized to ensure non-erosive velocities leaving forebay;  
 
#Sized to ensure non-erosive velocities leaving forebay;  
Line 63: Line 63:  
|Permanent Pool Depth
 
|Permanent Pool Depth
 
|Vegetation requirements, rapid settling
 
|Vegetation requirements, rapid settling
|The average permanent pool depth should range from 150 mm to 300 mm
+
|style="text-align: left|The average permanent pool depth should range from 150 mm to 300 mm
 
|-
 
|-
 
|Active Storage Depth
 
|Active Storage Depth
 
|Storage/flow control, sustaining vegetation
 
|Storage/flow control, sustaining vegetation
|Maximum 1.0m for storms < 10 year event
+
|style="text-align: left|Maximum 1.0m for storms < 10 year event
 
|-
 
|-
 
|Side Slopes  
 
|Side Slopes  
 
|Safety  
 
|Safety  
|
+
|style="text-align: left|
 
#5:1 For 3 m above and below permanent pool;  
 
#5:1 For 3 m above and below permanent pool;  
 
#Maximum 3:1 elsewhere
 
#Maximum 3:1 elsewhere
Line 77: Line 77:  
|Inlet  
 
|Inlet  
 
|Avoid clogging/freezing  
 
|Avoid clogging/freezing  
|
+
|style="text-align: left|
 
#Minimum 450 mm;  
 
#Minimum 450 mm;  
 
#Preferred pipe slope: >1%;  
 
#Preferred pipe slope: >1%;  
Line 84: Line 84:  
|Outlet  
 
|Outlet  
 
|Avoid clogging/freezing  
 
|Avoid clogging/freezing  
|
+
|style="text-align: left|
 
#Minimum: 450mm outlet pipe;  
 
#Minimum: 450mm outlet pipe;  
 
#Preferred pipe slope: >1%;  
 
#Preferred pipe slope: >1%;  
Line 92: Line 92:  
|Maintenance Access  
 
|Maintenance Access  
 
|Access for backhoes or dredging equipment
 
|Access for backhoes or dredging equipment
|
+
|style="text-align: left|
 
#Provided to approval of Municipality;  
 
#Provided to approval of Municipality;  
 
#Provision of maintenance drawdown pipe preferred
 
#Provision of maintenance drawdown pipe preferred
Line 98: Line 98:  
|Buffer  
 
|Buffer  
 
|Safety  
 
|Safety  
|Minimum 7.5 m above maximum water quality/erosion control water level
+
|style="text-align: left|Minimum 7.5 m above maximum water quality/erosion control water level
 
|}
 
|}
  
8,255

edits

Navigation menu