Changes

Jump to navigation Jump to search
m
Line 57: Line 57:  
|Length-to-Width Ratio
 
|Length-to-Width Ratio
 
|Maximize flow path and minimize short-circuiting potential
 
|Maximize flow path and minimize short-circuiting potential
|i) Overall: minimum 3:1; ii) Forebay: minimum 2:1
+
|
 +
#Overall: minimum 3:1;
 +
#Forebay: minimum 2:1
 
|-
 
|-
 
|Permanent Pool Depth
 
|Permanent Pool Depth
Line 69: Line 71:  
|Side Slopes  
 
|Side Slopes  
 
|Safety  
 
|Safety  
|i) 5:1 For 3 m above and below permanent pool (ii) Maximum 3:1 elsewhere
+
|
 +
#5:1 For 3 m above and below permanent pool;
 +
#Maximum 3:1 elsewhere
 
|-  
 
|-  
 
|Inlet  
 
|Inlet  
 
|Avoid clogging/freezing  
 
|Avoid clogging/freezing  
|i) Minimum 450 mm; ii) Preferred pipe slope: >1%; iii) If submerged, obvert 150 mm below expected maximum ice depth
+
|
 +
#Minimum 450 mm;  
 +
#Preferred pipe slope: >1%;  
 +
#If submerged, obvert 150 mm below expected maximum ice depth
 
|-
 
|-
 
|Outlet  
 
|Outlet  
 
|Avoid clogging/freezing  
 
|Avoid clogging/freezing  
|i) Minimum: 450mm outlet pipe; ii) Preferred pipe slope: >1%; iii) If orifice control used, 75mm diameter minimum; (iv) Minimum 100mm orifice preferable
+
|
 +
#Minimum: 450mm outlet pipe;  
 +
#Preferred pipe slope: >1%;  
 +
#If orifice control used, 75mm diameter minimum;  
 +
#Minimum 100mm orifice preferable
 
|-
 
|-
 
|Maintenance Access  
 
|Maintenance Access  
 
|Access for backhoes or dredging equipment
 
|Access for backhoes or dredging equipment
|(i) Provided to approval of Municipality; (ii) Provision of maintenance drawdown pipe preferred
+
|
 +
#Provided to approval of Municipality;  
 +
#Provision of maintenance drawdown pipe preferred
 
|-
 
|-
 
|Buffer  
 
|Buffer  
8,255

edits

Navigation menu